19
Chapter 4 Specification
2 -General Characteristic Parameters
3-Water Cooling Condition
No. Characteristics
Test conditions
Min. Nom. Max. Unit
1 Operating voltage
360
400
440
VAC
2
Input Power MFSC-2000W
100% Output
6.5
KW
Input Power MFSC-3000W
100% Output
10
KW
3 Operating ambient
temperature
10
40
℃
4 Operating ambient
relative humidity
10
85
%
5 Cooling method
Water-cooling
6 Storage temperature
-10
60
℃
7 Dimensions
482.6*850*172 (W*D*H)
mm
8
Weight MFSC-2000W
72 ±3
kg
Weight MFSC-3000W
80 ±3
kg
No.
Characteristics
Min.
Unit
1
Cooling Method
Water Cooling
2
Ambient Temperature
≥ 30
< 30
℃
Chiller Set Temperature
24-26 20-23
℃
3
Hydraulic pressure
≥ 4
bar
4
MFSC-2000W Water Flow Requirements
20
L/
min
MFSC-3000W Water Flow Requirements
25
5
MFSC-2000W Chiller Rated Cooling Capacity
Requirements
6.5
kw
MFSC-3000W Chiller Rated Cooling Capacity
Requirements
7.5
kw