11
Chapter 2 General Safety Information
Please note that any macroscopic attachment may cause extreme damage to
lens or burn the laser or any backward-stage light path equipment.
◎
For cleaning instructions of the lens, please refer to the "Optical Fiber
Connector Inspection and Cleaning Guide".
◎
Hot or molten pieces of metal may be produced when the laser is under
operation. Exercise caution if debris is produced in operation.
◎
When you carry out commissioning and calibration of the laser output, you
must set the laser output at low power level and then gradually increase the
output power during checking the quality of the light spot emitted from the laser
via an infrared viewer.
WARNING:
◎
Make sure that the individual protective equipment meets the output power
and wavelength range of the laser.
◎
Never look directly into the optical fiber or the collimator, and make sure you
wear the safety protective glasses in each operation.
4
、
Electrical Operating Instructions
We strongly recommend that you read the following procedures before operating
the laser:
1
、
Make sure the shell of this equipment is properly grounded. Any interruption
of the ground loop may result in personal injury.
2
、
Make sure the power source connecting equipment is properly grounded.
3
、
In order to further reduce fire hazard, replace the line fuses (if applicable)
with the same types and ratings. The use of other fuses or material is prohibited.
4
、
Make sure that the input AC voltage of the laser is the voltage of the normal
AC mains (Three-phase four-wire 360-440VAC), and wires are connected
accurately. Any incorrect wiring method may cause damage to people or
instrument.