28
Chapter 6 Operation Guide
◎
When operating the laser, do not directly look at the output fiber and wear
safety glasses. When wiring, please turn off all power switches of the laser.
Start steps are as follows:
1
、
Start the Chiller;
2
、
Remove the end cap of the collimator;
3
、
Make sure that the end surface of the collimator is clean and not covered
with impurities;
4
、
Make sure that the emergency stop switch is turned on;
5
、
Turn the rear panel power switch (POWER) to the ON position;
6
、
Place the Key Switch of the front panel on position "ON";
7
、
Press the START button on the front panel.
5-Mode Description
The working modes of the laser are as follows:
1. Continuous mode: the emitted light is continuous and can be used for cutting.
2. Pulse mode: The emitted light is pulsed. When the pulse frequency is greater
than a certain value, the actual application is used to control the average output
4-Start Steps
WARNING:
◎
Make sure that all the electrical connections (including cooling water
connections) are connected prior to use. All the connectors must be held steady
with screws if possible.