Setup
Connections
maxon motor control
ESCON Servo Controller
Document ID: rel7132
3-17
ESCON 36/3 EC Hardware Reference
Edition: November 2018
© 2018 maxon motor. Subject to change without prior notice.
Figure 3-6
Hall Sensor Input Circuit (analogously valid also for Hall Sensors 2 & 3)
Hall sensor supply voltage
+5 VDC
Max. Hall sensor supply current
30 mA
Input voltage
0…24 VDC
Max. input voltage
+24 VDC
Logic 0
typically <1.0 V
Logic 1
typically >2.4 V
Internal pull-up resistor
2.7 k
Ω
(a5.45 V − 0.6 V)