maxon motor
EPOS 24/1 Getting Started
EPOS Positioning Controller
6.4.5
Manual Tuning
If the auto-tuning shows an error or the result of the auto-tuning is not
sufficient, you have to tune the appropriate regulator manually. You have to
start an iterative search of the regulation gains. Change the system
parameters manually, start a single step movement and check the
recorded data.
Follow the next instructions:
a)
Choose the ‘Manual Tuning’ mode in the regulation tuning screen
and start the tuning.
Figure 44: Manual tuning mode
b)
Go to the ‘Next Evaluation Setting’ and change the regulation
gains of the appropriate regulator.
Figure 45: Manual tuning mode
Hints:
Start values for current and velocity regulator are normally not difficult to
find.
For positioning regulator, following rule of thumb will be helpful:
Start values:
‘Integral Gain’ = 0 ‘Proportional Gain’ = 2 x ‘Differential
Gain’
Overshoot:
Reduce the ‘Proportional Gain’ or increase the ‘Differential
Gain’.
Position Error:
Increase the ‘Proportional Gain’ and the ‘Differential Gain’.
Integral Gain:
Adjust the ‘Integral Gain’ at the end, if the other two gains
are optimized. Increase the ‘Integral Gain’ until the static
position error is small enough.
c)
Start a new movement and judge the recorded data.
Figure 46: Next tuning step
d)
Repeat this iteration until all regulation gains are optimized.
Edition July 2007 / Subject to change
maxon motor control
29