4
2.4
OVERALL DIMENSIONS AND MINIMUM CLEARANCES
The Maxol Supacombi HE 28 can be installed to a horizontal or
a vertical flue system. The different flue applications as shown in
Fig. 2a and Fig. 2b are available as a Horizontal Wall terminal
2.5
CONCENTRIC AIR / FLUE DUCT SPECIFICATIONS
2.5.1
UNIVERSAL TELESCOPIC WALL TERMINAL KIT (C
12
) - PART NO. 956120
kit or a V
ertical Concentric flue terminal kit comprising the
connecting parts to the appliance and end terminal.
1
2a
(C12) – P
ART NO. 956120
T
raditional concentric flue system, Fig. 2a, with a maximum length
of 2700mm. The flanged flue elbow is designed with 2.5° slope
towards the appliance so that the condensate can easily drain off.
When installing, please note that for every metre horizontal flue
length the terminal exit centreline is approx. 45 mm higher than
the elbow’s centreline.
The standard terminal is telescopic and can be used between
450 to 635 mm (from the centre of flue outlet to the outside wall,
but can be cut to a minimum flue length of 250mm, which is
suitable for single, 100mm (4"), brick walls.