2
Appliance
Maxol
Supacombi HE 28
Mode
Rate
Central Heating Output
Max
kW
28.3
(non-condensing)
(Btu/h)
(96600)
(80 - 60
°C)
Min
kW
12.1
(Btu/h)
(41300)
Central Heating Output (condensing)
Max
kW
30.7
(50 - 30
°C)
(Btu/h)
(104800)
Net
kW
29.0
Central Heating Input
(Btu/h)
(99000)
Max Rate
Gr
oss
kW
32.2
(Btu/h)
(110000)
Net
kW
13.0
Central Heating Input
(Btu/h)
(44400)
Min Rate
Gr
oss
kW
14.4
(Btu/h)
(49200)
Max
kW
28.3
Domestic Hot W
ater Output
(Btu/h)
(96600)
Min
kW
12.1
(Btu/h)
(41300)
Net
kW
29.0
Domestic Hot W
ater Input
(Btu/h)
(99000)
Max Rate
Gr
oss
kW
32.2
(Btu/h)
(110000)
Net
kW
13.0
Domestic Hot W
ater Input
(Btu/h)
(44400)
Min Rate
Gr
oss
kW
14.4
(Btu/h)
(49200)
Central Heating Gas Rate (after 10 min operation - hot)
m3/h
3.07
Max
ft3/h
(108.4)
Domestic Hot W
ater Gas Rate (after 10 min operation - hot)
m3/h
3.07
Max
ft3/h
(108.4)
Bur
ner Pressure (at 20mbar inlet pressure)
Max
10.0
Min
mbar
1.6
Ignition
6.0
Injectors
130
Seasonal Ef
ficiency
%
87.5
The appliance classification (as defined in EN 483) will be one of
the following depending on the chosen flue option: C
12
, C
32
.
This appliance is certified to comply with the requirements of EN
483, EN 677, and EN 625 for use in GB and IE (Great Britain
and Ireland) using gas category 2H (G20 with a governed gas
supply at 20 mbar (8 in.wg) inlet pressure).
TECHNICAL SPECIFICATIONS
2
2.1
GAS CATEGORIES
2.2
PERFORMANCE DATA