2
5,3TANDARD-!802/02/&02/-ATRIX))))NSTALL6ERSIONB
Safety - 1
ul 325 compliant installation
requirements
A )NSTALLTHEGATEOPERATORONLYWHEN
A .INSTALLEZLOUVREBARRIÒREQUESI
4HEOPERATORISAPPROPRIATEFORTHECONSTRUCTIONOFTHEGATEANDTHEUSAGE#LASSOFTHEGATE
LOUVREBARRIÒREESTAPPROPRIÏPOURLASTRUCTUREETLACLASSEDUTILISATIONDELABARRIÒRE
!LLOPENINGSOFAHORIZONTALSLIDEGATEAREGUARDEDORSCREENEDFROMTHEBOTTOMOFTHEGATETOAMINIMUMOFMFT ABOVETHEGROUND
TOPREVENTAMMINCH DIAMETERSPHEREFROMPASSINGTHROUGHTHEOPENINGSANYWHEREINTHEGATEANDINTHATPORTIONOFTHE
ADJACENTFENCETHATTHEGATECOVERSINTHEOPENPOSITION
TOUTESLESOUVERTURESDELABARRIÒRECOULISSANTESONTPROTÏGÏESOUGRILLAGÏESDUBASDELAPORTEJUSQUÌUNMINIMUMDEMPI DUSOL
SIBIENQUUNESPHÒREDEMMPO DEDIAMÒTRENEPEUTPASSERPARUNEOUVERTUREAUNIVEAUDELABARRIÒREETDELAPORTIONDELA
CLÙTUREADJACENTEQUELABARRIÒRECOUVREENPOSITIONOUVERTE
!LLEXPOSEDPINCHPOINTSAREELIMINATEDORGUARDEDAND
TOUSLESPOINTSDEPINCEMENTSONTÏLIMINÏSOUPROTÏGÏS
'UARDINGISSUPPLIEDFOREXPOSEDROLLERS
DESPROTECTIONSSONTFOURNIESPOURLESGALETSEXPOSÏS
B 4HEOPERATORISINTENDEDFORINSTALLATIONONLYONGATESUSEDFORVEHICLES0EDESTRIANSMUSTBESUPPLIEDWITHASEPARATEACCESSOPENING4HE
PEDESTRIANACCESSOPENINGSHALLBEDESIGNEDTOPROMOTEPEDESTRIANUSAGE,OCATETHEGATESUCHTHATPERSONSWILLNOTCOMEINCONTACTWITHTHE
VEHICULARGATEDURINGTHEENTIREPATHOFTRAVELOFTHEVEHICULARGATE
B ,OUVREBARRIÒREESTDESTINÏÌNÐTREINSTALLÏQUESURDESBARRIÒRESUTILISÏESPOURLESVÏHICULES)LFAUTFOURNIRUNEAUTREVOIEDACCÒSAUX
PIÏTONS,AVOIEDACCÒSPOURLESPIÏTONSDOITÐTRECON UEPOURFAVORISERLEPASSAGEDESPIÏTONS0LACEZLABARRIÒREDESORTEQUEPERSONNENE
PUISSEENTRERENCONTACTAVECLABARRIÒREPOURLESVÏHICULESSURLENSEMBLEDESATRAJECTOIRE
C 4HEGATEMUSTBEINSTALLEDINALOCATIONSOTHATENOUGHCLEARANCEISSUPPLIEDBETWEENTHEGATEANDADJACENTSTRUCTURESWHENOPENINGAND
CLOSINGTOREDUCETHERISKOFENTRAPMENT3WINGINGGATESSHALLNOTOPENINTOPUBLICACCESSAREAS
C 0OURRÏDUIRELESRISQUESDECOINCEMENTLORSDELOUVERTUREETDELAFERMETURELABARRIÒREDOITÐTREINSTALLÏEDANSUNENDROITOáLABARRIÒREET
LESSTRUCTURESAVOISINANTESSONTSUFFISAMMENTÏLOIGNÏESLUNEDELAUTRE,ESBARRIERSBATTANTESNEDOIVENTPASOUVRIRDANSUNEZONEDACCÒS
PUBLIC
D 4HEGATEMUSTBEPROPERLYINSTALLEDANDWORKFREELYINBOTHDIRECTIONSPRIORTOTHEINSTALLATIONOFTHEGATEOPERATOR$ONOTOVERTIGHTENTHE
OPERATORCLUTCHORPRESSURERELIEFVALVETOCOMPENSATEFORADAMAGEDGATE
D ,ABARRIÒREDOITÐTREBIENINSTALLÏEETFONCTIONNERLIBREMENTDANSLESDEUXDIRECTIONSAVANTDENTREPRENDRELINSTALLATIONDELOUVREBARRIÒRE
.ESERREZPASTROPLEMBRAYAGEOULASOUPAPEDESURPRESSIONDELOUVREBARRIÒREPOURCOMPENSERUNEBARRIÒREENDOMMAGÏE
E &ORGATEOPERATORSUTILIZING4YPE$PROTECTION
E 0OURLESOUVREBARRIÒRESQUIUTILISENTDESPROTECTIONSDETYPE$
4HEGATEOPERATORCONTROLSMUSTBEPLACEDSOTHATTHEUSERHASFULLVIEWOFTHEGATEAREAWHENTHEGATEISMOVING
LESCOMMANDESDELOUVREBARRIÒREDOIVENTÐTREPLACÏESDESORTEQUELUTILISATEURVOITLENSEMBLEDELAZONEDELABARRIÒRELORSQUECETTE
DERNIÒREESTENMOUVEMENT
4HEPLACARDASREQUIREDBYSHALLBEPLACEDADJACENTTOTHECONTROLS
LÏTIQUETTEREQUISESELONLACLAUSEDOITÐTREPLACÏEÌCÙTÏDESCOMMANDES
!NAUTOMATICCLOSINGDEVICESUCHASATIMERLOOPSENSORORSIMILARDEVICE SHALLNOTBEEMPLOYEDAND
UNDISPOSITIFDEFERMETUREAUTOMATIQUECOMMEUNEMINUTERIEUNEBOUCLEDEDÏTECTIONOUUNDISPOSITIFSIMILAIRE NEDOITPASÐTREUTILISÏ
.OOTHERACTIVATIONDEVICESHALLBECONNECTED
AUCUNAUTREAPPAREILDACTIVATIONNEDOITÐTRECONNECTÏ
F #ONTROLSINTENDEDFORUSERACTIVATIONMUSTBELOCATEDATLEASTMFT AWAYFROMANYMOVINGPARTOFTHEGATEANDWHERETHEUSERIS
PREVENTEDFROMREACHINGOVERUNDERAROUNDORTHROUGHTHEGATETOOPERATETHECONTROLS
F ,ESCOMMANDESDESTINÏESÌLACTIVATIONPARLUTILISATEURDOIVENTÐTRESITUÏESÌAUMOINSMPI DESPIECESMOBILESDELABARRIÒREETÌ
UNENDROITOáLUTILISATEURNEPEUTPASATTEINDRELESCOMMANDESPARLEDESSUSPARLEDESSOUSPARLESCÙTÏSETAUTRAVERSDELABARRIÒRE
%XCEPTION%MERGENCYACCESSCONTROLSONLYACCESSIBLEBYAUTHORIZEDPERSONNELEGFIREPOLICE%-3 MAYBEPLACEDATANYLOCATIONINTHE
LINEOFSIGHTOFTHEGATE
%XCEPTION,ESCOMMANDESDACCÒSDURGENCEACCESSIBLESAUPERSONNELAUTORISÏSEULEMENTPEXPOMPIERPOLICIER3-5 PEUVENTÐTRE
PLACÏESÌTOUTENDROITDANSLECHAMPDEVISIBILITÏDELABARRIÒRE
Summary of Contents for MATRIX III MAX 1500 PRO
Page 43: ...PQVGU ...