Polarity does
NOT
matter
4 5 6
C-1 NO1 NC1
LIGHT ON
SENSITIVITY
Min
Max
DARK ON
Power
Set switch to
“LIGHT ON”
24 to 240 VAC
24 to 240 VDC
1
C-1
2
3
NC1
Sensitivity Adjustment:
If the photocell does not respond to an
obstruction, lower the sensitivity by
turning adjustment counter-clockwise.
OK to
use
12VDC
GND
Photocell (Reflector)
OPENING Direction
NOTE: To meet the UL 325 2018 standard,
Type B1 Non-Contact sensor entrapment
protection device MUST be MONITORED
by the gate operator.
Installation Steps:
1.
Set switch to “LIGHT ON”
2.
Wire 12V power to photocell
3.
Wire
OPEN ONLY 10K
to photocell
NC1
Wire
GND
to photocell
C-1
4.
Align photocell to reflector
5.
Adjust sensitivity
10K Resistor wiring to E3K Photocell
UL325-2018
OPEN ONLY
NC
OPEN ONLY
10K
PHOTO CLS
NC
OPEN/CLS
NC
GND
12VDC OUT
GND
CLS ONLY
10K
OPEN/CLS
10K
12VDC OUT
UL SENSOR N.C.
UL SENSOR 10K
P
P
P
P
12VDC OUT
NC2N02 C2
omron E3K-R10K4 wiring for max pro
UL 2018 Label on packaging
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7b
25
Summary of Contents for MATRIX III MAX 1500 PRO
Page 43: ...PQVGU ...