DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver
45 of 344
9.1.1 Ethernet Interface Clock Modes
The Ethernet PHY interface has several different clocking requirements, depending on the mode of operation.
Table 9-1
outlines the possible clocking modes for the Ethernet Interface. The buffered REF_CLKO output is
generated by division of the 100MHz system clock input by the user on SYSCLKI. The frequency of the
REF_CLKO pin is automatically determined by the DS33R11 based on the state of the RMIIMIIS pin. The
REF_CLKO function can be turned off with the
GL.CR1
.RFOO bit. Note that in DCE and RMII operating modes,
the REF_CLKO signal should not be used to provide an input to REF_CLK, due to the reset requirements in these
operating modes.
In RMII mode, receive and transmit timing is always synchronous to a 50 MHz clock input on the REF_CLK pin.
The source of REF_CLK is expected to be the external PHY. The user has the option of using the 50MHz
REF_CLKO output as the timing source for the PHY. More information on RMII mode can be found in
Section
9.15.2
.
While using MII mode with DTE operation, the MII clocks (RX_CLK and TX_CLK) are inputs that are expected to
be provided by the external PHY. While using MII mode with DCE operation, the MII clocks (TX_CLK and
RX_CLK) are output by the DS33R11, and are derived from the 25MHz REF_CLK input. More information on MII
mode can be found in Section
9.15.1
.
9.1.2 Serial Interface Clock Modes
The serial interface timing is determined by the line clocks. Both the transmit and receive clocks (TCLKE and
RCLKI) are inputs, and can be gapped.