Table 25. HDCP Register Table (MAX9281 Only) (continued)
REGISTER
ADDRESS
SIZE
(Bytes)
NAME
READ/
WRITE
FUNCTION
DEFAULT
VALUE
(hex)
0x95
1
ACTRL
Read/write
D3 = RESET_HDCP
1 = Reset HDCP circuits. Automatically set to 0 upon
completion.
0 = Normal operation
0x00
D2 = START_AUTHENTICATION
1 = Start authentication. Automatically set to 0 once
authentication starts.
0 = Normal operation
D1 = VSYNC_DET
1 = Internal falling edge on VSYNC detected
0 = No falling edge detected
D0 = ENCRYPTION_ENABLE
1 = Enable encryption
0 = Disable encryption
0x96
1
ASTATUS
Read only
D[7:4] = Reserved
0x00
(Read only)
D3 = V_MATCHED
1 = V matches V’ (when EN_INT_COMP = 1)
0 = V does not match V’ or EN_INT_COMP = 0
D2 = PJ_MATCHED
1 = PJ matches PJ’ (when EN_INT_COMP = 1)
0 = PJ does not match PJ’ or EN_INT_COMP = 0
D1 = R0_RI_MATCHED
1 = RI matches RI’ (when EN_INT_COMP = 1)
0 = RI does not match RI’ or EN_INT_COMP = 0
D0 = BKSV_INVALID
1 = BKSV is not valid
0 = BKSV is valid
0x97
1
BCAPS
Read/write
D[7:1] = RESERVED
0x00
D0 = REPEATER
1 = Set to one if device is a repeater
0 = Set to zero if device is not a repeater
0x98 to 0x9C
5
ASEED
Read/write
internal random number generator optional seed value
0x0000000000
0x9D to 0x9F
3
DFORCE
Read/write
Forced video data transmitted when FORCE_VIDEO = 1.
R[7:0] = DFORCE[7:0]
G[7:0] = DFORCE[15:8]
B[7:0] = DFORCE[23:16]
0x000000
0xA0 to 0xA3
4
V.H0,
V’.H0
Read/write
H0 part of SHA-1 hash value.
V (read only) of the transmitter when EN_INT_COMP = 0
V’ (read/write) of the receiver when EN_INT_COMP = 1
0x00000000
MAX9277/MAX9281
3.12Gbps GMSL Serializers for Coax or
STP Output Drive and LVDS Input
www.maximintegrated.com
Maxim Integrated │
69