3-12 Maintenance & Troubleshooting
MN605
Tachometers:
DC, AC and digital outputs are available. These can be mounted to our motors
or shipped separately. Tachs help the SCR control achieve more precise speed
regulation than by armature feedback alone.
Transparent Brush Inspection:
For easy brush inspection and commutation monitoring without disassembly of
the motor.
Winding RTD
RTD (Resistance Temperature Detector) devices are used to measure or
monitor the temperature of the motor winding during operation.
Winding Thermocouple
s
Used to measure or monitor winding temperatures.
Winding Thermostat
Temperature device that activates when winding temperatures are excessive.
Used with an external circuit to warn of excessive winding temperature or to
shut down a motor.
Reflash Instructions
Instructions to reflash the residual magnetism for
Lifting Magnet Generators only
.
These generators are self
−
exciting. If voltage will not build up, it is possible the residual
magnetism is insufficient to initiate excitation. This procedure is to restore sufficient
residual magnetism to self excite.
Note: Loss of residual magnetism can be caused by misconnection (reversing the
connections) of F1 and F4.
1.
Disconnect F1 and F4. All other leads may remain connected.
2.
Connect 24 to 40VDC power source positive lead to F1 and negative to F4.
DC source may be batteries, a DC welder (not AC) or rectified AC.
3.
Drive generator at rated RPM.
4.
Measure the voltage across A1 and A2. Voltage should be 150 to 200% of F1
to F4 voltage. When A1 to A2 voltage level reaches this level (approximately
30 seconds) carefully remove the source leads, an arc may be present during
disconnect.
5.
Stop the generator.
6.
Reconnect F1 and F4 as shown in the DC Generator Connection Diagram.
Rotation is viewed from opposite drive end (commutator end) A1 is positive for
CCW rotation. A2 is positive for CW rotation. S1 is always negative.
Shown for CCW (counterclockwise) rotation, (viewed from opposite drive end or
commutator end). For CW (clockwise) rotation, interchange leads A1 and A2.
DC Generator Connection Diagram
Compound Wound Short Shunt Connection
Shunt Fields
ARM
COMM Field
Series Field
60
Summary of Contents for Magic Finger Bagger
Page 14: ...14...
Page 15: ...15...
Page 16: ...16...
Page 17: ...17...
Page 36: ...Integral Horsepower DC Motor Installation Operating Manual 5 05 MN605 36...
Page 48: ...Section 1 General Information 2 6 Installation Operation MN605 48...
Page 66: ...66...
Page 67: ...67...
Page 68: ...68...
Page 69: ...69...
Page 70: ...70...
Page 71: ...71...
Page 72: ...72...
Page 73: ...73...
Page 74: ...74...
Page 75: ...75...
Page 76: ...76...
Page 81: ...81...
Page 84: ...DECAL REORDER SHEET DECAL NUMBER DECAL IDENTIFICATION D001 D002 D003 D004 D005 84...
Page 85: ...DECAL REORDER SHEET DECAL NUMBER DECAL IDENTIFICATION D006 D007 D008 D009 85...