11. Cord arrangement of the connecting cord for
power / supply and the connecting cord for
controller.
*The two types of wires are to be arranged with the massage block set in its upper most
position (in respect to the chair).
1. Connect the two connectors, (a) and (c) to Main PCB.
2. Install the ground wires (d).
3. Fix the Cord wire for chair side on the Back frame.
4. Grasp white mark on the Connecting cord for power supply by
large cable tie and then fix them on the Back frame.
5. Bind two cords with two lead wires of massage clutch and up/
down sensor by using a small cable tie.
24