7
Command reference
47
MN1 Command
This command allows receiving the output voltage monitor with 000
H
to FFF
H
(12 bit)
(Syntax) MN1
(Return
)
①
MONI1=FFFH (Monitor
value)
= (maximum rated voltage)
②
MONI1=7FFH
(Monitor value) = (half of maximum rated voltage)
MN2 Command
This command allows receiving the output current monitor with 000
H
to FFF
H
(12 bit).
(Syntax) MN2
(Return)
①
MONI2=FFFH (Monitor
value)
= (maximum rated current)
②
MONI2=7FFH
(Monitor value) = (half of maximum rated current)
VM Command
This command allows receiving output voltage monitor with 0.0 to 100.0%(increment of 0.01%)
(Syntax) VM
(Return)
①
VM=100.0
(Monitor value) = (maximum rated voltage)
②
VM=12.34
(Monitor value) = (12.34% of maximum rated voltage)
③
VM=25.0
Output voltage is a quarter of the rated
(Description)
0 value of 2 decimal point is not displayed(Return
③
)
IM Command
This command allows receiving output current monitor with 0.0 to 100.0%(increment of 0.01%)
(Syntax) IM
(Return)
①
IM=100.0
Output current is a maximum of the rated
②
IM=12.34
(Monitor value) = (12.3% of maximum rated current)
③
IM=25.0
Output current is a quarter of the rated
(Description)
0 value of 2 decimal point is not displayed(Return
③
)
VGET Command
This command allows receiving output voltage monitor with 0.0 to rated voltage(V)
(Syntax)
VGET
In case of range 20V/20A (increment of 0.01V)
(Return)
①
VGET=20.0
(Monitor value) = (20V)
②
VGET=12.34
(Monitor value) = (12.34V)
(Description)
0 value of 2 decimal point is not displayed(Return
①
)
* Minimum setting value of VGET command is different for
each model ,RK(400W/800W/1200W)/REK/REKJ.
(See Section “
7-3
Minimum setting / return value for each
command”.)
IGET Command
This command allows receiving output current monitor with 0.0 to rated current(A)
(Syntax)
IGET
In case of range 20V/20A (increment of 0.01A)
(Return)
①
IGET=20.0
(Monitor value) = (20A)
②
IGET=12.34
(Monitor value) = (12.34A)
(Description)
0 value of 2 decimal point is not displayed(Return
①
)
* Minimum setting value of IGET command is different for
each model ,RK(400W/800W/1200W)/REK/REKJ.
(See Section “
7-3
Minimum setting / return value for each
command”.)