5
Program
26
5
Program
5-1
Summary of Syntax
For example, following programming set the output voltage of the unit to rated maximum voltage.
①
Input delimiter.
・
GPIB
connection
GPIB
delimiter
(See Section “
4-5
Settings address and delimiter for GPIB(CO-G32/CO-G32m)
”)
・
RS-232C
CR(0D
H
)
・
LAN
connection
CR(0D
H
)
・
USB connection(Lus1 Option)
CR(0D
H
)
②
Some commands require a parameter.
③
Wrong commands are to be ignored.
④
Specify the UNIT number.
・
Standard Digital Interface/LGob Option
#0 to #31, or #AL
・
LUs1/LEt
Option Do
not
specify
Caution
Number of letters for one command shall be maximum 20 excluding delimiter.
If the number of letter exceed 20, then letters of multiple of 20, for example 20th, 40th, 60th,
…
letter from the top shall be ignored and rest of the letters are input.
(
Syntax
)
#1
VCN
12.3456789012345
CR(0D
H
)
Total 25 letters.
↓
345
CR(0D
H
)
20 letters are to be ignored,
and balance 5 letters are to
be input.
(
Description
)
In the above case “345 CR(0D
H
)” is considered as invalid command,
and input shall be ignored.
5-2
Multiple command
By using “AL” for UNIT number, command is sent to all the unit connected.
(Syntax)
①
#AL CH0 FFFF
All units set to a maximum of rated voltage.
②
#AL SW1
All units enables to output.
(Description)
Commands applicable to Multiple command are :
CH0, CH1, CH2, CH7, VCN, ICN, OVP, OCP, VSET, ISET, OVPSET,
OCPSET, SW, REN, GTL, DELAY, TON, TOFF, SLAVE
#OO CH0 FF OO
②
Parameter
③
Command
④
Unit number
①
Delimiter