Preparing the Worktop
Cut out the work surface following the dimensions shown in the drawing below.
For the purpose of installation and use, a minimum distance of 5 cm space must be left around
the cut out.
Be sure the thickness of the work surface is at least 30 mm. Use a heat-resistant work surface
material to avoid deformation caused by the heat from the hob. The minimum distance
between the hob and the cupboard should be at least 50 cm.
Ensuring Adequate Ventilation
Always make sure the induction cooker hob is well ventilated and that the air inlet and outlet
are not blocked. This hob requires an adequate supply of fresh, cool air to fully function. The
base of the hob must have direct unrestricted ventilation to the room where the hob is installed.
Follow the requirements below.
56 cm
+0.4
+0.1
49 cm
+0.4
+0.1
5cm (min)
5cm (min)
5cm (min)
5cm (min)
Cupboard
Hob
50 cm (min)
5mm
5cm
2 cm (min)
Heat
Resistant
Board
There are ventilation holes around the outside of the hob. YOU MUST ensure that these
holes are not blocked by the worktop, when you put the hob into position.