Matrix ETERNITY Quick Start
9
In ETERNITY PE
•
To set the BRI Ports of ETERNITY PE as TE or NT, refer the tables below to
change the position of the jumpers on the main board of the BRI Card. Default:
all ports are set as TE.
Common Instructions for installing the BRI card in ETERNITY ME, GE,
and PE
•
A BRI Port can be configured in the TE/NT mode. Depending on the installation
and configuration scenario, Termination Resistance of 100
should be inserted.
•
When the BRI Port is configured as Network, NT mode, power may have to be
fed to the terminal equipment connected to the BRI port.
Inserting Termination Resistance on the BRI Port
•
Termination Resistance should be inserted in the following cases
1.
When the BRI port is configured in
NT
mode.
2.
When the BRI port is configured in
TE
mode and connected in a
Point-to-Point
configuration as shown in figure 1.
Figure 1:
Mode
Jumper Position
BRI Port 1
BRI Port 2
J1
J2
J4
J5
J7
J8
J10
J11
NT
BC
BC
BC
BC
BC
BC
BC
BC
TE
AB
AB
AB
AB
AB
AB
AB
AB
Summary of Contents for ETERNITY GE
Page 1: ...ETERNITY Quick Start ...
Page 2: ......
Page 3: ...ETERNITY The IP PBX with Seamless Mobility and Universal Connectivity Quick Start ...
Page 8: ...2 Matrix ETERNITY Quick Start ...
Page 58: ...52 Matrix ETERNITY Quick Start ...
Page 90: ...84 Matrix ETERNITY Quick Start ...
Page 91: ...Matrix ETERNITY Quick Start 85 Appendix Universal Slots ETERNITY ME16S ETERNITY ME10S ...
Page 93: ...Matrix ETERNITY Quick Start 87 ETERNITY PE6S ETERNITY PE3SP ETERNITY PE3SS ...
Page 123: ...Matrix ETERNITY Quick Start 117 ...