MSC-HD42L Product Manual
>E 1
>
3.15 Firmware Command
Query the system firmware version.
Example
>Firmware
5.0.6
>
3.16 FrameIP Command
Query or assign the remote router IP address. Usually only used on Remote Panel devices or in conjunction
with the
to create a dual router 3D system. Sets the IP address of the Router system
which the button panel will connect to and control (or which the router will synchronize to when using the
RemoteSync command). This can also be enabled on Router systems with a local button panel to configure the
Router's panel to control a different Router (set to 0.0.0.0 by default to disable remote control and control the
Router device itself). This setting is saved and recalled on power up.
Command
Description
FrameIP
Query IP address of remote Router system to control.
FrameIP IP
Set IP address of remote Router system to control (use 0.0.0.0 on Router systems to disable
remote control).
Example to query and assign the remote Router IP
>FrameIP
192.168.2.60
>FrameIP 192.168.2.61
>
3.17 Gateway Command
Query or assign the network Gateway IP address. This is usually only needed on Remote Panel systems which
control a Router device on a different network. This setting is saved and recalled on power up.
Command
Description
Gateway
Query IP address of network Gateway.
Gateway IP
Set IP address of network Gateway.
3.18 Help Command
Display command reference information.
3.19 IP Command
Page 28 of 55