background image

 

 

Ruggedized Reader User’s Manual 

 

2003 Matrics, Inc. 

7

 

Section 4. Installation 

The instructions provided in this section describe a generic installation of the Ruggedized Reader. For 
installation instructions specific to a Clamp Truck application, refer to the 

Clamp Truck Application 

User’s Manual

 (DCN: MNI03H003) for more information. For installation instructions specific to a 

Reader Station application, refer to the 

Reader Station Application User’s Manual

 (DCN: 

MNI03H004) for more information. 

Getting Started 

Follow the steps listed below (and detailed in the following sections) to install your Ruggedized 
Reader: 

1.  Mount the Reader in a location chosen for optimal surveillance. 
2.  Connect antenna(s) to the Ruggedized Reader. 
3.  Connect the Ruggedized Reader to your host computer. 
4.  Power on the Ruggedized Reader. 

Mount the Ruggedized Reader 

Before mounting the Ruggedized Reader, you must select a location for it. For best results, consider 
the following when determining the optimal placement for your antennas and Ruggedized Reader: 

• 

Make sure that you follow the FCC guidelines for antenna placement. Antennas should be at 
least 45 centimeters from trained personnel and 100 centimeters from all other persons. 

• 

Mount the Ruggedized Reader as close as possible to your antennas in order to minimize 
cable lengths. 

CAUTION:

 

If the Ruggedized Reader is not installed properly, it could 

be damaged and your system performance diminished. 

To mount the Ruggedized Reader: 

1.  Position the Ruggedized Reader (PN: RDR-RUG-100) at the desired mounting position on the 

wall, shelf, portal structure, or clamp truck, etc..  

2.  Using the pre-drilled holes at the corners of the Reader, slide through four (4) 10-32 screws for 

mounting the Ruggedized Reader. 

3.  Securely affix the Ruggedized Reader to the selected location using the four (4) 10-32 screws 

with lock washers and bolts. 

Summary of Contents for RDR-RUG-100

Page 1: ...edized Reader User s Manual Revised October 6 2003 Document Control Number MNI03H001 Matrics Inc 8850 Stanford Boulevard Suite 3000 Columbia MD 21045 Tel 410 872 0300 Fax 410 872 0700 http www matrics...

Page 2: ...for identification purposes only and are the trademarks of their respective owners Statement of Rights IMPORTANT READ CAREFULLY Matrics products incorporate technology that is protected by U S patent...

Page 3: ...5 Ruggedized Reader Diagram Back View 6 LEDs 6 SECTION 4 INSTALLATION 7 Getting Started 7 Mount the Ruggedized Reader 7 Connect Antenna s to the Ruggedized Reader 8 Connect the Reader to a Host Compu...

Page 4: ...This page left intentionally blank iv Ruggedized Reader User s Manual 2003 Matrics Inc...

Page 5: ...n this User s Manual ACRONYM DEFINITION IC Integrated Circuit MVM Matrics Visibility Manager OOK On Off Keyed RFID Radio Frequency Identification TBD To Be Determined References For additional informa...

Page 6: ...or use with industrial control equipment The Ruggedized Reader offers superior and robust read range capabilities anti collision features and very high data read rates unmatched by other systems It pr...

Page 7: ...from Matrics PN RDR STA 100 Refer to the Reader Station User s Manual DCN MNI03H002 for more information about the Reader Station Refer to the Reader Station Application User s Manual DCN MNI03H004 f...

Page 8: ...UL approved compound against windblown dust and rain Vibration Withstands sinusoidal vibration to the following specifications o IEC 68 2 6 MIL STD 810E Method 514 4 o 10 55 Hz 0 15mm 03 91g o 55 500...

Page 9: ...Purpose I O Connector Two 2 Receive Antenna Connectors Front View 11 long includes connectors x 6 5 wide x 3 deep includes bridge Data Link LED Tag Read LED Error LED Bridge from Transmit Output to RF...

Page 10: ...Power LED Green LED is lit when the Reader is powered on and receiving power Data Link LED Green LED flashes as it communicates and indicates a good link Error LED Amber LED is lit to indicate a bad l...

Page 11: ...gedized Reader Before mounting the Ruggedized Reader you must select a location for it For best results consider the following when determining the optimal placement for your antennas and Ruggedized R...

Page 12: ...der Make sure that you unplug the power supply or power off the clamp truck to power off the system first before disconnecting cables Connect the Reader to a Host Computer The steps you must follow to...

Page 13: ...ately protected medical devices Consult a physician or the manufacturer of the medical device if you have any questions Other electronic equipment may also be subject to interference Radio Station Lic...

Page 14: ...rial Authorization RMA You must obtain a return material authorization RMA number from Matrics Customer Service refer to the Contact Us section in this User s Manual before you return any parts for re...

Page 15: ...eshooting In the event that you encounter a problem with your system refer to the following table for possible solutions PROBLEM POSSIBLE CAUSE SOLUTION TBD TBD TBD Ruggedized Reader User s Manual 200...

Page 16: ...Inc Section 8 Contact Us For sales service and technical assistance contact Matrics at Tel 410 872 0300 Monday Friday 8 30 a m 5 00 p m EST Fax 410 872 0700 http www matrics com Matrics Inc 8850 Stan...

Reviews: