5 ERROR MESSAGES
The console keeps a list of the last 6 errors which may have occurred.
The error messages are displayed in order on the first line of the LCD in alternation with other messages on the
display, for example:
1 / 2 ALL 04 then for example 2 / 2 ALL 06
These flashing messages indicate, for example, that first there was an interruption in the BYP knob circuit,
followed by a lost trolley.
The following table lists the exceptions which may occur during and operation cycle, and the respective
messages displayed.
The list of events is intended to indicate a sequence of the errors which occur, in order to assist with the
reconstruction of events in case of malfunction.
Type
Description
Conditions
Actions
L
o
ck
in
g
Suspen
sion
Display
SC on flow
valve
A short circuit has been
detected on the flow valve.
Yes
No
Timeout on
flow valve
opening
The limit time for flow
valve opening has been
exceeded (par. C#2 or par.
C#4).
No
No
The limit time for flow
valve closing has been
exceeded (par. C#3 or par.
C#5).
Timeout on
flow valve
closing
Yes
No
S C
o n
b y p a s s
valve
A short circuit has been
detected on the flow valve.
No
No
Yes
No
Timeout on
b y p a s s
v a l v e
opening
No
No
S p e e d
adjustment
limit
End of stroke reached for
bypass valve without
reaching the required
speed
Trolley lost
N o p u l s e s f o r s o m e
time(par. C#8 or par. C#9).
If no pulses are received
for a time such as par. C#8
an average speed measured
as the minimum threshold
is set
Yes
No