Commande
Reply
Remarks
SYS_<date_time>_S<state_sistem
>_V<speed_o_height>_L<length>_ST<
date_time_beginning>_ET<data_ora_fin
e> <date_time> date and time of the
system <state_sistem > state of the system
indicates the state either:
0 = system stopped
1 = opening of bypass and start
2 = closing flow and start
3 = starting time
4 = flow opening
5 = starting pause
6 = bypass adj.
7 = bypass adj. on
8 = opening of bypass and end
9 = final pause
10 = closing flow and end
11 = opening of bypass and adj.stop
12 = closing flow and adj.stop
13 = idle waiting for adj.stop
14 = opening flow start adj. again
15 = closing flow in an emergency
16 = opening flow in an emergency
17 = idle for emergency
18 = error
19 = error causing a lockup
20 = error causing a suspension
<speed_o_height> speed of tube windup
<lunghezza> length of the unwound tube
<Date_time_beginning> date and time
for the process to begin
<Date_time_beginning> date and time
for the process to end
S<number_
>_<speed_o_height
> <number_sector> sector in process
<Speed_o_height> value of the set
parameter
sector