background image

 

8

 

Maintain Mode (Float Mode Monitoring)

When the internal battery is fully charged 

and the jump starter display shows “100”, 

the charger has started maintain mode. In 

this mode, the charger keeps the battery 

fully charged by delivering a small current 

when necessary. If the charger has to 

provide its maximum maintain current for 

a continuous 12 hour period, it will go into 

abort mode (see 

Aborted Charge

). This 

is usually an indication of a bad battery; 

have the jump starter checked.

5.4  Charging the Internal Battery  

While Driving

You may also charge the internal battery 

while driving, using a male-to-male 

charger cable (not included). 

IMPORTANT:

 DO NOT CHARGE THE 

INTERNAL BATTERY FOR MORE THAN 

30 MINUTES OR LEAVE THE BATTERY 

UNATTENDED. IT COULD EXPLODE, 

CAUSING PROPERTY DAMAGE OR 

PERSONAL INJURY. 

1. 

Make sure the car is running.

2. 

Insert one end of the accessory cable 

into the 12V DC power outlet. 

3. 

Insert the other end of the accessory 

cable into the vehicle’s accessory 

outlet (lighter socket). 

NOTE:

 Using this method to charge the 

battery overrides the maintain mode and 

the battery can be overcharged. 

4. 

Monitor the progress of the charge by 

pressing the Percentage of Charge 

button on the front of the unit. Do not 

leave the battery unattended or it could 

explode, causing property damage and 

personal injury. When the battery is 

fully charged, disconnect the accessory 

cable from the jump starter, and then 

from the lighter socket of the vehicle. 

NOTE:

 Completely disconnect the charger 

cable when the engine is not running. 

 

6.  OPERATING INSTRUCTIONS

 

6.1  Jump Starting a Vehicle Engine

IMPORTANT:

 Using the jump starter 

without a battery installed in the vehicle will 

damage the vehicle’s electrical system.

IMPORTANT: 

Do not use the jump starter 

while charging its internal battery.

1. 

Turn the vehicle’s ignition OFF before 

making cable connections.

2. 

Make sure the rotary switch on the 

front of the jump starter is in the OFF 

position. Connect the jump starter to 

the battery, following the precautions 

listed in section 3.

WARNING! RISK OF EXPLOSION.

If you have connected the clips backward, 

an audio alarm will sound. 

DO NOT turn 

the rotary switch to the 12V (12V or 

24V for model PS4444JS) position.

 

This could cause serious damage to the 

jump starter or the vehicle. Reverse the 

connections and the audio alarm will stop.

3. 

If no audio alarm sounds, turn the 

rotary switch to the 12V position (12V 

or 24V position for model PS4444JS). 

The clips are now powered.

4. 

Crank the engine. If the engine does not 

start within 3-8 seconds, stop cranking 

and wait at least 1 minute before 

attempting to start the vehicle again. 

(This permits the battery to cool down.)

5. 

After the engine starts, turn the rotary 

switch to the OFF position. Disconnect 

the black clip (-), then the red clip (+) in 

that order, and clip them back onto the 

jump starter storage holders.

6. 

Recharge the jump starter as soon as 

possible after use.

NOTE: 

If the cables are connected to a 

24 volt system when the switch is in the  

12 volt position, the audio alarm will 

sound continuously. TURN OFF the jump 

starter immediately or internal battery 

damage could occur.

NOTE:

 If the switch is in the 12V or 24V 

position or the jump starter is connected to 

a battery for more than five minutes, four 

beeps will sound. This is a reminder to turn 

the jump starter off and/or disconnect it 

from the vehicle’s battery when not in use.

WARNING! RISK OF EXPLOSION.

To prevent sparking, NEVER allow the 

clips to touch together or to contact the 

same piece of metal. Never attempt to 

jump start a frozen battery.

6.2  Powering A 12V DC Device:

The jump starter is a power source for all 

12V DC accessories that are equipped 

with a 12V accessory plug. Use it for 

power outages and fishing or camping 

trips. Estimated usage time is listed in the 

following chart.

1. 

Make sure the device to be powered 

is OFF before inserting a 12V DC 

accessory plug into the 12V DC socket.

2. 

Ensure the battery clips are securely 

clipped on the storage holders.

3. 

Open the protective cover of the 12V DC 

power outlet on the front of the jump 

starter.

4. 

Plug the 12V DC device into the 12V 

DC power outlet, and turn on the 12V 

DC device (if required).

5. 

If the 12V DC device draws more than 

15A or has a short circuit, the internal 

Summary of Contents for PS2222JS

Page 1: ...o utilizar el arrancador con seguridad y eficacia Por favor lea y siga las siguientes instrucciones y precauciones ESSAYER DE GARDER LE MANUEL D INSTRUCTIONS ET LE LIRE AVANT CHAQUE UTILISATION Ce man...

Page 2: ...WARNING Possible explosion hazard Contact with battery acid may cause severe burns and blindness Keep out of reach of children ADVERTENCIA Posible riesgo de una explosi n El contacto con una bater a...

Page 3: ...RGAR LA BATERIA INTERNA DEL ARRANCADOR 17 INSTRUCCIONES DE OPERACI N 18 INSTRUCCIONES DE MANTENIMIENTO 20 INSTRUCCIONES PARA EL MANEJO Y ALMACENAMIENTO 20 LOCALIZACI N Y SOLUCI N DE PROBLEMAS 21 ESPEC...

Page 4: ...repair is required Incorrect reassembly may result in a risk of fire or electric shock WARNING RISK OF EXPLOSIVE GASES 1 11 To reduce the risk of a battery explosion follow these instructions and tho...

Page 5: ...SPARK NEAR THE BATTERY MAY CAUSE A BATTERY EXPLOSION TO REDUCE THE RISK OF A SPARK NEAR THE BATTERY 3 1 Attach the output cables to the battery and chassis as indicated below Never allow the output c...

Page 6: ...is most accurate when the jump starter has been disconnected from all devices and charging sources for a few hours To check the voltage level of the jump starter s internal battery make sure the clips...

Page 7: ...enough for the AC ampere rating of the charger as specified Length of cord feet 25 50 100 150 AWG size of cord 18 18 18 16 AWG American Wire Gauge 5 2 Charging the Jump Starter with included Charger 1...

Page 8: ...ection 3 WARNING RISK OF EXPLOSION If you have connected the clips backward an audio alarm will sound DO NOT turn the rotary switch to the 12V 12V or 24V for model PS4444JS position This could cause s...

Page 9: ...are electrically live and should be covered with an insulator to prevent the connectors from touching metal or each other and causing a short circuit 1 Connect the Memory Saver 12V plug to your 12V D...

Page 10: ...icle s battery is defective Check for poor connection to battery and frame Make sure connection points are clean Check the battery charge status by pressing the Display button on the front of the unit...

Page 11: ...the battery to cool The battery may be too large or have a short circuit Have battery checked or replaced The battery capacity is too low or the battery is too old Have it checked or replaced The bat...

Page 12: ...24V Cold Cranking Amps 525 12V 350 24V Battery Hookup Cables 2 AWG 60 152 cm Dimensions H x W x D 16 7 x 12 9 x 7 4 42 5 x 33 x 19 cm Weight 39 68 lbs 18 kg Charger Input voltage 120V AC 60Hz 0 5A Ou...

Page 13: ...r or if this unit is resold through an unauthorized retailer Manufacturer may void this Limited Warranty if a warranty void if removed label is removed from the product Manufacturer makes no other war...

Page 14: ...cay o si sufri da os de cualquier otra forma h galo revisar por una persona capacitada que efect e reparaciones 1 10 No desarme la unidad h galo revisar por una persona capacitada que efect e reparac...

Page 15: ...e 2 15 Lea comprenda y siga todas las instrucciones para el arrancador la bater a el veh culo y cualquier equipo que se utilice cerca de la bater a y la unidad 2 16 Determine el voltaje de la bater a...

Page 16: ...de la bater a Cuando no se conecta a una bater a la pantalla digital puede usarse para indicar el porcentaje de carga de la bater a interna del arrancador Para verificar el estado de carga de la bate...

Page 17: ...tomacorriente adecuadamente instalado y que cuente con descarga a tierra de acuerdo con todas las ordenanzas y c digos Los pasadores del enchufe deben adaptarse al recept culo tomacorriente No utiliz...

Page 18: ...n per odo continuo de 12 horas pasar al modo de interrupci n v ase la secci n Carga Anulada Esto es ocacionalmente causado por una p rdida de energ a en la bater a o la bater a est da ada Esto suele s...

Page 19: ...ante apagones pesca o d as de campo El tiempo aproximado de uso se describe en la siguiente gr fica 1 Aseg rese de que el dispositivo a alimentar est APAGADO antes de insertar un enchufe accesorio de...

Page 20: ...antenimiento desenchufe y desconecte la unidad ver secciones 3 y 4 7 2 Utilice un pa o seco para limpiar la corrosi n de toda la bater a y otra suciedad o aceite de los terminales cables y carcasa de...

Page 21: ...queo de la bater a La unidad no pone a funcionar mi aparato de 12V El aparato de 12V no enciende La bater a de la unidad no est cargada El aparato de 12V absorbe m s de 15A o tiene un corto circuito E...

Page 22: ...de sobrecalienta Si es as deje que la bater a se enfr e La bater a puede ser demasiado grande o tener un circuito en corto Verif quela o reempl cela La capacidad de la bater a es demasiado bajo o la b...

Page 23: ...rranque en fr o 525 12V 350 24V Cables de conexi n de la bater a Calibre 2 AWG 60 152 cm de largo Dimensiones Altura x Ancho x Profundidad 16 7 x 12 9 x 7 4 42 5 x 33 x 19 cm Peso 39 68 libras 18 kg C...

Page 24: ...no autorizado El fabricante pudiera anular esta Garant a Limitada si la etiqueta warranty void if removed es removida del producto El Fabricante no realiza ninguna otra garant a incluidas a t tulo enu...

Page 25: ...n choc violent est tomb parterre ou a t endommag d une autre fa on apportez le un technicien qualifi 1 10 Ne pas d monter le aide de d marrage apportez le chez un technicien qualifi quand vous devez l...

Page 26: ...nt au manuel d utilisation de votre v hicule et assurez vous que la tension de sortie du booster est correcte 2 17 Assurez vous que les pinces des c bles du aide au d marrage sont fermement connect es...

Page 27: ...tilis pour indiquer le de charge de la batterie interne du d marreur Pour v rifier le statut de charge de la batterie interne assurez vous que le commutateur rotatif est en position OFF puis appuyez s...

Page 28: ...rectement install e et conforme tous les codes et r glements locaux Les broches de la fiche doivent tenir le r ceptacle la sortie Ne pas utiliser avec un syst me non mis la terre DANGER Ne modifiez ja...

Page 29: ...urant selon les besoins Si le chargeur est tenu de fournir son maximum de maintenir un courant continu d une p riode de 12 heures il se mettra en mode Arr t voir l article Arr t du Chargement Il s agi...

Page 30: ...mping Dur e d utilisation estim e est list dans le tableau suivant 1 S assurer que le dispositif soit tient avant de brancher la prise de l accessoire 12 V CC dans l autre 2 S assurer que les pinces d...

Page 31: ...er la garde de m moire et l utilisation d un chiffon sec pour essuyer toutes les salet s ou l huile des connecteurs et le c ble NOTE Le garde de m moire 12V DC fiche contient un fusible de 8 amp res 7...

Page 32: ...onne connexion la batterie La batterie Interne n est pas charg e La batterie du v hicule est d fectueuse V rifiez mauvaise connexion la batterie et le ch ssis Assurez vous que les points de connexion...

Page 33: ...court circuit Faites v rifier la batterie ou remplacez la La capacit de la batterie est trop faible ou la batterie est trop vieille Faites la v rifier ou remplacez la La batterie ne conservera pas sa...

Page 34: ...525 12V 350 24V C bles de raccordement la batterie 2 AWG 60 152 cm de long Dimensions H x L x P 16 7 x 12 9 x 7 4 42 5 x 33 x 19 cm Poids 39 68 lbs 18 kg Chargeur Tension d entr e 120V CA 60Hz 0 5A T...

Page 35: ...revendu par un d taillant non autoris Le fabricant peut annuler la garantie si l tiquette warranty void if removed est retir e du produit Le fabricant ne fait aucune autre garantie y compris mais sans...

Reviews: