Temperature Controller
METICOM TM10 Module
TM10 Temperature Control Module
CAUTIONS
Please read the instructions carefully before any operation.
If there are any signs indicating that the temperature control module has been damaged during
transportation, please do not power on it.
Before the temperature control module is powered on, please
1) Confirm if the power supply of the mainframe meets the requirements;
2) Confirm that the mold-power & thermocouple cables are connected reliably and the wiring style on
controller mainframe is the same as on the mold.
3) Ensure that the fan of mainframe is in working condition.
The temperature control module is set to be automatic closed-loop control mode before shipping.
The temperature control module will show the code of the expected thermocouple type, please check it
and adjust the related setting according to this manual if it does not match the system.
If the temperature control module alarms during working, please check the alarm code and analyze the
cause.
Before you pull out or insert the temperature control module, please turn off the module’s power and
the circuit breaker on the mainframe.
Module Operation
1. Specifications
◆
Power requirements: AC85~250V, 50/60Hz
◆
Sensor type: J or K thermocouple
◆
Setting range: 0
℃
~450
℃
(32
℉
~842
℉
)
◆
Measurement accuracy: ±0.25%F.S.
◆
Cold-junction compensation accuracy: ±1
℃
◆
Control mode: Auto PID or Manual
◆
Control accuracy: ±0.25%F.S.
◆
Control output device: Triac
◆
Load capability: 15A, 50W~1650W(110V)
,
100W~3600W(240V)
◆
Operating temperature: 0
℃
~55
℃
(32
℉
~131
℉
)
◆
Operating humidity: 10~80%, non-condensing
◆
Storage temperature: -20
℃
~70
℃
(-4
℉
~158
℉
)