  Temperature Controller 

 METICOM TM10 Module 

TM10 Temperature Control Module

CAUTIONS 

Please read the instructions carefully before any operation.

If there are any signs indicating  that the temperature control module has been  damaged during
transportation, please do not power on it.

Before the temperature control module is powered on, please
1) Confirm if the power supply of the mainframe meets the requirements;
2) Confirm that the mold-power & thermocouple cables are connected reliably and the wiring style on
controller mainframe is the same as on the mold.
3) Ensure that the fan of mainframe is in working condition.

The temperature control module is set to be automatic closed-loop control mode before shipping.

The temperature control module will show the code of the expected thermocouple type, please check it

and adjust the related setting according to this manual if it does not match the system.

If the temperature control module alarms during working, please check the alarm code and analyze the

cause.

Before you pull out or insert the temperature control module, please turn off the module’s power and

the circuit breaker on the mainframe.

Module Operation 

1. Specifications

 

Power requirements: AC85~250V, 50/60Hz

 

Sensor type: J or K thermocouple

 

Setting range: 0

~450

 (32

~842

)

 

Measurement accuracy: ±0.25%F.S.

 

Cold-junction compensation accuracy: ±1

 

Control mode: Auto PID or Manual

 

Control accuracy: ±0.25%F.S.

 

Control output device: Triac

 

Load capability: 15A, 50W~1650W(110V)

  100W~3600W(240V)

 

Operating temperature: 0

~55

 (32

~131

)

 

Operating humidity: 10~80%, non-condensing

 

Storage temperature: -20

~70

 (-4

~158

)

Summary of Contents for METICOM TM10

Page 1: ...Hot Runner Temperature Controller with METICOM TM10 module User Guide Ver 1 01...

Page 2: ...ic equipment you must observe standard safety procedures to protect both yourself and the equipment Cautions Service and installation of this equipment should only be performed by qualified service pe...

Page 3: ...nel of the mainframe This diagram indicates the input voltage configuration that was prewired at the factory Make sure it matches what you ordered 3 INSTALLATION 1 You are installing a piece of electr...

Page 4: ...Page 4 Copyright Mastip Technology Limited Information subject to alteration V3 51a www mastip com Temperature Controller METICOM TM10 Module 4 BACK PANEL WIRING...

Page 5: ...Page 5 Copyright Mastip Technology Limited Information subject to alteration V3 51a www mastip com Temperature Controller METICOM TM10 Module 5 TYPICAL SYSTEM WIRING DIAGRAM...

Page 6: ...teration V3 51a www mastip com Temperature Controller METICOM TM10 Module 6 Default CONNECTOR WIRING can be customized Combination Power Thermocouple Connector 16 or 24 Pin Separate Power Thermocouple...

Page 7: ...le is set to be automatic closed loop control mode before shipping The temperature control module will show the code of the expected thermocouple type please check it and adjust the related setting ac...

Page 8: ...m Thermocouple reverse alarm Temperature high alarm Temperature low alarm Heater fault alarm Heating invalid alarm High alarm of ambient temperature High limit of load current High limit of output per...

Page 9: ...trol is an open loop system and requires no thermocouple feedback signal It can be used when thermocouple is failed or without thermocouple in system The controller s PV displays present temperature v...

Page 10: ...difying the setting until new alarm happens 3 ALL low deviation alarm value When present value SV ALL the buzzer is beeping No alarm when power on or after modifying the setting until new alarm happen...

Page 11: ...be changed quickly by press DISP key 9s 2 C F temperature unit 0 1 3 Sot soft start heater dehumidify function 0 Off 1 10 On soft start time Sot 80s Notes The rest of soft start time reduced to one th...

Page 12: ...0 the controller will auto start standby mode until the operator end it by pressing MODE key 0 Off filtering value Std s number in the tens place ones place Used to reduce the influence of interferen...

Page 13: ...ng make Snb 0 if the connection is right E r H Yes Thermocouple open Check the sensor or switch to manual control mode E r L Yes Thermocouple inverse H E A HEA No Heater fault Check the heater t r S Y...

Reviews: