  Temperature Controller 

 METICOM TM10 Module 

MAINFRAME

1. GENERAL DESCRIPTION

This controller is designed as a closed-loop power distribution and temperature controlling system. It
provides the user with premier temperature control capabilities.

This unit has one or more heavy duty connectors (rated 10A or16A) on back, used to connect with the
mold by mold-power & thermocouple cables.

This unit has one or more built-in cooling fans, one or two circuit breakers and power input cable. Neon
indicators illuminate after power on.

 Heavy Duty Connector 

  

Power Input Cable 

2. UNPACKING & INSPECTION

1) After unpacking, inspect your mainframe and check for any damage that has occurred during shipment.
2) Check the circuit breaker and neon phase voltage indicators for damage.
3) Check for proper operation of circuit breaker by flipping breaker on and off with no voltage applied.
4) Check power output connector and thermocouple input connector for any physical damage.
5) Check AC input power configuration. The power input diagram is located on the back panel of the

mainframe. This diagram indicates the input voltage configuration that was prewired at the factory.
Make sure it matches what you ordered.

3. INSTALLATION

1) You are installing a piece of electronic equipment which is delicate and should not be subjected to any

physical or environmental abuse. Select a cool, dry, well ventilated, environmentally clean location,
away from heat, moisture and liquid carrying lines, i.e.: water cooling hoses, hydraulic hoses, etc.

2) Unless  customized,  all controllers will be configured  for a  power supply with single-phase 3-wire

208~240Vac for 1~2  zones controller, and either  3-phase 5-wire  380~415Vac  or  3-phase 4-wire
200-240Vac for 3~48 zones controller.
Please follow the power supply configuration on the back panel.
If the configuration of power supply needs to be re-wired, please follow the back panel wiring diagram
in this manual.

3) Route AC input cable to a branch circuit (service) disconnect switch and attach leads to fused side of

switch. Be sure ground lead is attached to a good earth ground.

4) Connect power & thermocouple cables to mainframe and mold.

WARNING: Before applying power, make sure all international and local electrical codes have been followed 

and all safety precautions are taken. 
IMPORTANT: For mold wiring and heater connection information, refer to mold connector wiring diagram. 

Summary of Contents for METICOM TM10

Page 1: ...Hot Runner Temperature Controller with METICOM TM10 module User Guide Ver 1 01...

Page 2: ...ic equipment you must observe standard safety procedures to protect both yourself and the equipment Cautions Service and installation of this equipment should only be performed by qualified service pe...

Page 3: ...nel of the mainframe This diagram indicates the input voltage configuration that was prewired at the factory Make sure it matches what you ordered 3 INSTALLATION 1 You are installing a piece of electr...

Page 4: ...Page 4 Copyright Mastip Technology Limited Information subject to alteration V3 51a www mastip com Temperature Controller METICOM TM10 Module 4 BACK PANEL WIRING...

Page 5: ...Page 5 Copyright Mastip Technology Limited Information subject to alteration V3 51a www mastip com Temperature Controller METICOM TM10 Module 5 TYPICAL SYSTEM WIRING DIAGRAM...

Page 6: ...teration V3 51a www mastip com Temperature Controller METICOM TM10 Module 6 Default CONNECTOR WIRING can be customized Combination Power Thermocouple Connector 16 or 24 Pin Separate Power Thermocouple...

Page 7: ...le is set to be automatic closed loop control mode before shipping The temperature control module will show the code of the expected thermocouple type please check it and adjust the related setting ac...

Page 8: ...m Thermocouple reverse alarm Temperature high alarm Temperature low alarm Heater fault alarm Heating invalid alarm High alarm of ambient temperature High limit of load current High limit of output per...

Page 9: ...trol is an open loop system and requires no thermocouple feedback signal It can be used when thermocouple is failed or without thermocouple in system The controller s PV displays present temperature v...

Page 10: ...difying the setting until new alarm happens 3 ALL low deviation alarm value When present value SV ALL the buzzer is beeping No alarm when power on or after modifying the setting until new alarm happen...

Page 11: ...be changed quickly by press DISP key 9s 2 C F temperature unit 0 1 3 Sot soft start heater dehumidify function 0 Off 1 10 On soft start time Sot 80s Notes The rest of soft start time reduced to one th...

Page 12: ...0 the controller will auto start standby mode until the operator end it by pressing MODE key 0 Off filtering value Std s number in the tens place ones place Used to reduce the influence of interferen...

Page 13: ...ng make Snb 0 if the connection is right E r H Yes Thermocouple open Check the sensor or switch to manual control mode E r L Yes Thermocouple inverse H E A HEA No Heater fault Check the heater t r S Y...

Reviews: