  Temperature Controller 

 METICOM TM10 Module 

WARRANTY 

We warrant that this product will be free from defects in materials and workmanship for a period of two (2) 
years from the date of shipment. If any such product proves defective during this warranty period, we, at 
our option, either will repair  the defective product without charge for parts and labor or  will provide a 
replacement in exchange for the defective product.   

This warranty shall not apply to any defect, failure or damage caused by improper use or improper or 
inadequate maintenance and care. We shall not be obligated to furnish service under this warranty; a) to 
repair damage resulting from attempts by personnel other than our representatives to repair or service the 
product; b) to repair damage resulting from improper use or connection to incompatible equipment; or c) to 
service a product that has been modified or integrated with other products when the effect of such 
modification or integration increases the time or difficulty of servicing the product.     

This warranty excludes replacement of fuses, triac, calibration, contact points and damage to the 
module from the use of improper styles of fuses. The maximum allowable fuse rating is 15 amps. Lower 
ratings may be used for improved protection.   

SAFETY 

Our products have been designed to be safe and simple to operate. As with any electronic equipment, you 
must observe standard safety procedures to protect both yourself and the equipment.   

Cautions: 

 

Service and installation of this equipment should only be performed by qualified service personnel
familiar with high voltage electrical circuits.

 

All international and local electrical codes must be followed when connecting this equipment.

 

Only persons with knowledge of the system's operation and capabilities should operate the system.

 

Read all of these instructions before connecting power and turning on the system.

 

Unless specifically explained in this manual or directed by us,  do not attempt to repair the system
yourself. Doing so could result in damage to the system, or serious personal injury.

To Prevent Injuries: 

 

Do not apply voltage to a terminal that exceeds the range specified for that terminal.

 

Do not operate this product with covers or panels removed. All unused slots of a main frame must be
covered with the appropriately sized blank panels.

 

Do not operate this product when wet.

 

Do not operate this product in an explosive atmosphere.

To Prevent Product Damage: 

 

Do not operate this product from a power source that applies more than the voltages specified.

 

Do not connect thermocouples to any live areas of the heaters. Lock out and tag the controller and mold
and make sure there is electrical insulation between the thermocouple and any live areas.

 

After turning on the system, you should make sure that fans are running.

 

Never allow the fan outlets on the unit become blocked, this is where the system's cooling airflow exits.
If this area of the mainframe becomes cluttered and insufficient airflow or the system maybe damaged.

Summary of Contents for METICOM TM10

Page 1: ...Hot Runner Temperature Controller with METICOM TM10 module User Guide Ver 1 01...

Page 2: ...ic equipment you must observe standard safety procedures to protect both yourself and the equipment Cautions Service and installation of this equipment should only be performed by qualified service pe...

Page 3: ...nel of the mainframe This diagram indicates the input voltage configuration that was prewired at the factory Make sure it matches what you ordered 3 INSTALLATION 1 You are installing a piece of electr...

Page 4: ...Page 4 Copyright Mastip Technology Limited Information subject to alteration V3 51a www mastip com Temperature Controller METICOM TM10 Module 4 BACK PANEL WIRING...

Page 5: ...Page 5 Copyright Mastip Technology Limited Information subject to alteration V3 51a www mastip com Temperature Controller METICOM TM10 Module 5 TYPICAL SYSTEM WIRING DIAGRAM...

Page 6: ...teration V3 51a www mastip com Temperature Controller METICOM TM10 Module 6 Default CONNECTOR WIRING can be customized Combination Power Thermocouple Connector 16 or 24 Pin Separate Power Thermocouple...

Page 7: ...le is set to be automatic closed loop control mode before shipping The temperature control module will show the code of the expected thermocouple type please check it and adjust the related setting ac...

Page 8: ...m Thermocouple reverse alarm Temperature high alarm Temperature low alarm Heater fault alarm Heating invalid alarm High alarm of ambient temperature High limit of load current High limit of output per...

Page 9: ...trol is an open loop system and requires no thermocouple feedback signal It can be used when thermocouple is failed or without thermocouple in system The controller s PV displays present temperature v...

Page 10: ...difying the setting until new alarm happens 3 ALL low deviation alarm value When present value SV ALL the buzzer is beeping No alarm when power on or after modifying the setting until new alarm happen...

Page 11: ...be changed quickly by press DISP key 9s 2 C F temperature unit 0 1 3 Sot soft start heater dehumidify function 0 Off 1 10 On soft start time Sot 80s Notes The rest of soft start time reduced to one th...

Page 12: ...0 the controller will auto start standby mode until the operator end it by pressing MODE key 0 Off filtering value Std s number in the tens place ones place Used to reduce the influence of interferen...

Page 13: ...ng make Snb 0 if the connection is right E r H Yes Thermocouple open Check the sensor or switch to manual control mode E r L Yes Thermocouple inverse H E A HEA No Heater fault Check the heater t r S Y...