1  GENERAL INFORMATION 

1.1 

Product description 

The Mass Sine Ultra is a sine wave inverter. It converts DC 
energy from the battery into AC output power. 
  

1.2 

Use of this manual 

Copyright © 2015 Mastervolt. All rights reserved. 
Reproduction, transfer, distribution or storage of part or all of 
the contents in this document in any form without the prior 
written permission of Mastervolt is prohibited. 
 
This manual serves as a guideline for the safe and effective 
use and installation of the Mass Sine Ultra: 

  For the installer this manual gives directions for the 

installation, operation and commissioning. 

  For the end user, this manual gives directions for the 

operation, maintenance and possible correction of minor 
malfunctions. 

  Every person who works with the device should be 

familiar with the contents of this manual, and must 
carefully follow the instructions contained herein. 

  Store the manual in an accessible place. 

 

1.3 

Validity of this manual 

This manual is valid for the following model:  
 

Part no 

Model 

26024000  

Mass Sine Ultra 24/4000 

 
All the specifications, provisions and instructions contained 
in this manual apply solely to the Mastervolt-delivered 
standard version of a single Mass Sine Ultra. 

 

1.4 

Scope of warranty 

Mastervolt assures the product warranty of the Mass Sine 
Ultra during two years after purchase, on the condition that 
all instructions and warnings given in this manual are taken 
into account during installation and operation. 
Among other things, this means that installation is carried 
out by a qualified electrician, that installation and 
maintenance are executed according to the stated 
instructions and correct working sequence, and that no 
changes or repairs may have been performed on the Mass 
Sine Ultra other than by Mastervolt. The warranty is limited 
to the costs of repair and/or replacement of the product by 
Mastervolt only. 
Costs for installation labour, shipping of the defective parts 
and indirect damage are not covered by this warranty. For 
making an appeal on warranty you can contact your supplier 
directly, stating your complaint, application, date of purchase 
and part number / serial number. 
 

1.5 

Liability 

Mastervolt accepts no liability for: 

  consequential damage due to use of the Mass Sine 

Ultra; 

  possible errors in the manuals and the results thereof. 

 

1.6 

Changes to the Mass Sine Ultra 

Changes to the Mass Sine Ultra may be carried out only after 
obtaining the written permission of Mastervolt. This is not 
applicable for DIP-switches which are used for user settings. 
 

1.7 

Identification label 

 

 

 

Figure 1-1: Example of an identification label 

 
The identification label is positioned at the right side of the 
Mass Sine Ultra, see figure 1-1. 
 

CAUTION! 

Never remove the identification label. 
 

 

Summary of Contents for Mass Sine Ultra 24/4000

Page 1: ...w mastervolt com products inverters sine wave DE Siehe www mastervolt com products inverters sine wave FR Voir www mastervolt com products inverters sine wave ES Vea www mastervolt com products invert...

Page 2: ...W MASS SINE ULTRA Figure 0 1 Overview of the Mass Sine Ultra 1 Display with front switch 6 Fan 3x 2 Battery negative 7 Ground stud 3 Battery positive 8 Sync connector 2x 4 AC output 9 MasterBus connec...

Page 3: ...9 3 6 Daily use MasterBus monitoring 10 4 INSTALLATION 11 4 1 Unpacking 11 4 2 Environment 11 4 3 Wiring 11 4 4 Things you need 12 4 5 Removal of the front lid 12 4 6 Mounting the cabinet to a surface...

Page 4: ...guration via dip switches 20 6 2 MasterBus configuration 21 7 COMMISSIONING DECOMMISSIONING 23 7 1 Commissioning 23 7 2 Decommissioning 23 7 3 Trouble shooting 23 8 TECHNICAL DATA 25 8 1 Specification...

Page 5: ...t warranty of the Mass Sine Ultra during two years after purchase on the condition that all instructions and warnings given in this manual are taken into account during installation and operation Amon...

Page 6: ...s not hold itself liable for any damage resulting from the above 2 3 Organizational measures The user must always have access to the user s manual be familiar with the contents of this manual This app...

Page 7: ...ra parts and or to commit to undertake such testing as a part of the manufacturing process In addition the manufacturer must agree to indemnify and not hold Mastervolt responsible for any claims arisi...

Page 8: ...rs at the front side of the housing If the Mass Sine Ultra is activated and as long as none of the red indicators are illuminated no failure is detected and the unit is operating normally 3 3 1 AC Out...

Page 9: ...ver and under voltage See specifications The Mass Sine Ultra switches off if the DC input voltage is out of range 3 4 4 Dynamic DC input window Figure 3 4 Dynamic DC input window The Mass Sine Ultra w...

Page 10: ...m Index General Device state The state of your Mass Sine Ultra Standby Inverting Alarm Overload Low battery 1 1 16 Inverter Option to switch Off the inverter to prevent depleting of your batteries On...

Page 11: ...e mounted in such a way that obstruction of the airflow through the ventilation openings will be prevented No objects must be located within a distance of 10 cm 4 inch around the Mass Sine Ultra Keep...

Page 12: ...rth terminal PE GND to the hull or the chassis with a minimum 10 mm CAUTION For safe installation it is necessary to connect the neutral conductor N of the AC output to the earth PE GND insert a Resid...

Page 13: ...owermost bolts 5 Fasten all bolts securely 6 Fix cabinet to the surface with remaining two bolts 4 7 Wiring instructions WARNING Have installation work done by a licensed electrician only Before conne...

Page 14: ...8 Installation overview Figure 4 8 Installation overview for one Mass Sine Ultra CAUTION Ensure correct polarities cross sections and fuses for all wiring An RCD according to local regulations must be...

Page 15: ...ly flexible for extended system configuration Mastervolt also offers several interfaces like the Modbus interface making even non MasterBus devices suitable to operate in the MasterBus network For cen...

Page 16: ...ly unlimited three phase power can be made available 5 2 General installation guidelines When using Mass Sine Ultra s in a multiple configuration the following requirements are Only identical Mass Sin...

Page 17: ...the communication module As you see the MasterBus network has a terminator on both ends Figure 5 4 Three Mass Sine Ultra s connected in 3 phase 5 5 Multi Mass Sine Ultra communication Within the Maste...

Page 18: ...proposed If not enough Mass Sine Ultra s are available for the cluster the topology needs approval Needs approval Needs approval approved Phase L1 L2 L3 shows in 3 ph cluster only Phase groups with sc...

Page 19: ...or parallel settings of two Mass Sine Ultra s See table below and section 6 1 MasterBus configuration is necessary for more Mass Sine Ultra s in a parallel connection By operating the DIP switches you...

Page 20: ...out in the menu When a DIP switch is set to 0 the corresponding MasterBus setting becomes default too regardless the previous setting 6 1 Configuration via dip switches The DIP switches are located i...

Page 21: ...oltage AC voltage 230 V 180 260 V Frequency AC frequency 50 Hz 50 Hz 60 Hz Energy save mode Option to enable Energy save mode Not checked Not checked checked Scanning below The Mass Sine Ultra starts...

Page 22: ...ot inside the unit Check all connections System error Internal Mass Sine Ultra error Contact your Mastervolt supplier 6 2 2 List of event sources This is the Mass Sine Ultra list of event sources Thes...

Page 23: ...ne Ultra out of operation follow the instructions in order of succession as described below 1 Move the Main switch of the Mass Sine Ultra to Off 2 Remove DC distribution fuses and or disconnect the ba...

Page 24: ...erting Errors Mass Sine Ultra shuts down 1 and 3 red 2 yellow Over temperature Mass Sine Ultra too hot Restart when alarm is over Check ventilation Reduce load 1 and 3 red System error Sync error Conf...

Page 25: ...al DC current at full load 200 A Recommended batteries 200 600 Ah No load DC drain Off mode hard switched 0 W Inverter off mode remote 4 W Normal operation mode 16 W Parallelling 3 phase Parallel stac...

Page 26: ...EN Mass Sine Ultra 26 8 2 Dimensions Figure 8 1 Dimensions in mm...

Page 27: ...ft 77042500 MasterBus connection cable UTP patch cable 25 m 82 ft 77045000 100 m 330 ft MasterBus cable UTP cable 77040010 MasterBus RJ45 conn 8 pole 25 pcs 77040015 Cover for RJ45 conn set a 25 st 77...

Reviews: