15
120/240 VOLT SYSTEMS - Plug-in Instructions
Plug-In Instructions for 120V GFCI cord set (optional)
Franklin / Revere / Madison
1. Electrical Requirements -
Your spa requires a dedicated 120 volt AC 15 AMP
electrical outlet and must have a separate, dedicated, grounded circuit having no other
appliance connected in the circuit. If you do not have a dedicated 120 volt AC 15 AMP
circuit, a licensed electrician should be called in to install the necessary wiring in
conformity with all applicable codes.The outlet must also have a ground wire in order to
take advantage of the designed safety features of the spa.
2. Electrical Precautions -
Your spa can be supplied with an optional 15 ft. line cord
with a built in GFCI. Locate the spa near a weather protected outlet, but no closer than 5
ft.
Do not use an extension cord!
Using an extension cord is hazardous and will
decrease the amount of power to the unit, causing slow heating, poor pump performance,
or system malfunction and will void the warranty.
Make sure the line cord does not lie across a walkway or in a heavily traveled area where
it may be a safety hazard or become damaged.To prevent the skirt from resting on the
cord, make sure that the cord passes through a cord opening in the bottom of the equip-
ment compartment.
WARNING
The continuous service ground wire is located in the line cord supplied.
DO NOT modify this cord in any way! Tampering with the ground wire or using an
adaptor which would make the built in grounding device ineffective would cause
electrical shock. Such modification would also nullify the warranty.
MS Owners Manual 12/5/03 1:57 PM Page 15