4. USING THE GENERATOR
4.1 M
ANUAL
STARTING
THE
GENERATOR
Before starting the generator check that all the doors is
closed.
Push the
green
button (
ref.1
).
The electric radiator fan will start immediatelly.
The genset will starts automatically after a little glowplug-
preheating delay.
Proper functioning of the generator will be signalled by the
generator functioning LED coming on (
ref.2
). When the above
operations are carried out, the generator safety switches
are automatically activated
(see the
chap 5
on “
Safety switches”
).
Repeated unsuccessful starting attempts may cause
excessive accumulation of water in the exhaust system
with possible serious damage
to the engine.
Do not make more than 5 consecutive starting attempts
as you may damage the starter motor.
During the running-in period (the first 50 hours), do not
apply loads exceeding 70% of the rated power of the
generator.
For more detailed information, consult the manual
provided by the engine manufacturer, which
accompanies each generator.
4.2 S
TOPPING
T
HE
G
ENERATOR
Stop the generator by pressing the
red
button on
the remote control panel (
ref.3
).
After one minute from the stopping, the control panel
will go in autopower off.
Before stopping the generator, it is advisable to run it
for a few minutes without drawing current in order to
allow gradual cooling of the engine and the alternator.
4.3 Emergency stop
The generator can be stopped with an emergency onboard
switch (
ref.4
). It is possible to fit another emergency remote
button connecing directly on clamp (
ref.5
) on pin
1-2
removing
the bridge (
ref.6
).
See wiring diagram for more details.