![Marzhauser Sensotech TANGO 3 mini Operating Manual Download Page 21](http://html.mh-extra.com/html/marzhauser-sensotech/tango-3-mini/tango-3-mini_operating-manual_1734687021.webp)
TANGO Desktop
Technical Data
Märzhäuser Sensotech GmbH
21
Power supply
Motor voltage
20.1…28.9 V DC
1
Starting current limitation
Starting current limitation makes "hot plugging" of the external power supply
possible
Measurement of current
consumption
Current consumption can be read by software
1
1
The current consumption depends on motor type, motor current, voltage supply, number of motors, number of revolutions,
current consumption of peripherals etc.. The following applies as a guidance value: I
max
@ 24 V = approx. 1/3 × sum
of all motor cu 0.2 A for logic vo 0.1 A per encoder (without further peripherals). Separate measurements
must always be made.