5
Problem:
Erratic vertical movement
Cause:
Another Laser Transmitter providing additional signal
Solution:
Check for another Laser Transmitter on the job site
Cause:
Radical Elevation changes
Solution:
Slowdown in rough terrain
Cause:
Laser beam reflection
Solution:
Check for mirrored surfaces
Problem:
Hydraulics do not respond when AUTOBLADE
button is pushed
Cause:
JD Tractors Only
Solution:
Tractor must be moving at least 1 MPH
If you are still experiencing problems with your system please call
us at (805) 583-0808 and we can assist you further.
Specifications
Input Power:
12 or 24 VDC Operation
Negative Ground
Nominal 10 amp minimum current
Note: If using 24VDC make sure to order correct Valves and Masts
Requirement:
10 amps Maximum
Output Hydraulic Drive: 5 amp Maximum per valve solenoid
2.5 amp maximum, if signal duration exceeds
two minutes
1 amp maximum output during short circuit
condition
Temperature Range:
20 to 50 Degrees C
Summary of Contents for Laser Tech 304
Page 8: ...Revised 11 2019 ...