3
5
Valve Type
00- Standard Valve - Blade Toggle
Disables Auto Blade
01- Proportional Valve - Blade Toggle
Disables Auto Blade
10- Standard Valve - Auto Blade button
Disables Auto Blade
11- Proportional Valve - Auto Blade
button disables Auto Blade
(Default setting is 01)
6
Survey Type
00- Manual data entry - (+) key records
elevation
01- Automatic - To set the interval push
(+) key once, drive a distance and
push (+) key again. Elevation will be
now recorded automatically during
that set interval.
02- Continuous - Records elevation
every two seconds.
USE THIS
SETTING WITH GRADEPLANE
SOFTWARE
03- GPS/Laser No Code
04- GPS/ Laser L Code
05- GPS/Laser M Code
06- Dual 304 Master
07- Dual 304 Slave
08- GPS Only L Code
09- GPS Only M Code
(Default setting is 01)
7
GPS Only - Max Change for GPS input
(Default setting is 10)
8
GPS Only - Blade Speed Gain
(Default setting is 04)
9
GPS Only - Center Width
(Default setting
Grading
Set your blade on a grade hub and move the sensor to center. The
green light on your panel will light up indicating you are now on grade.
Press the AUTOBLADE button and the light above Auto Blade will
illuminate. The hydraulics will now take over blade control. Press the
AUTOBLADE button or Blade toggle when you are ready to exit Auto
Blade Control.
Summary of Contents for Laser Tech 304
Page 8: ...Revised 11 2019 ...