background image

24

G

AS

  A

PPLIANCE

  I

NSTALLATION

W

ARNING

:

  Improper installation or operation of a gas appliance in this fireplace can allow unburned gas to leak

out which will cause a fire or explosion hazard, or the release of poisonous carbon monoxide into the dwelling
which can cause serious injury or death to its inhabitants.  To reduce these risks to a minimum, the following
important notices and instructions should be read and followed carefully.

I

MPORTANT

 N

OTICES

:

1. The provision for a gas line is intended for connection to a decorative gas appliance which and complies

with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces, ANSIZ21.60.   If a
decorative gas appliance is installed, it must be installed in accordance with the National Fuel Gas Code,
ANSIZ223.1.

C

AUTION

:

  “When a decorative gas appliance is installed, the fireplace damper must be fixed in a manner

which will maintain the minimum permanent vent opening at all times."

If an unvented gas appliance (blue flame) is installed it must incorporate an automatic shutoff device, and
must be installed in accordance with with the National Fuel Gas Code Z223.1, Latest edition.

C

AUTION

:  If an unvented gas appliance is installed in the fireplace, the gas appliance must only be operated

with the fireplace glass door fully open (if included).  Only unvented gas log set which have been found to
comply with the standard for unvented room heaters, ANSI/IAS/AGA Z21.11.2, are to be installed in this
fireplace.  When an approved ANSI/IAS/AGA Z21.11.2 unvented room heater is installed in this fireplace,
a  H2853 CANOPY must also be installed.

W

ARNING

:

    Do not operate an unvented gas log set in this fireplace with the chimney removed.

The installer of the fireplace and gas appliance must describe the operation of the fireplace and appliance
to the people who will be operating them and leave all instruction manuals with the operator of the appliance.

2. An approved gas shut off valve must be located outside the fireplace in an area accessible to the users of

the fireplace.

3. All gas piping and fitting must be either steel or malleable iron.  Unions must be of the ground joint type.

4. Some code authorities prohibit or place restrictions on the use of gas appliances in fireplaces.  Check with

local code authorities before proceeding with the installation.

5. The gas appliance and all connecting gas piping should only be installed by a licensed gas appliance

installer.

The following instructions only apply to passing the gas line through the fireplace wall.  Follow the instructions
provided by the appliance for the gas line, testing and adjusting it.

1. Locate the recessed area in the side refractory panel as shown by Figure 25.

2. Tap out a round hole in the brick liner with a hammer by tapping lightly on the recessed area.

3. Remove the two screws that hold the cover plates on the jacket wrap and discard the cover plate.

4. Use a screwdriver or similar tool to push the loose insulation out of the tube between the firebox and the

outer jacket of the fireplace.

5. Install the gas pipe through the tube between the firebox and jacket.

6. Attach the gas appliance to the gas pipe according to the appliance makers instructions.

53D9028. Rev 1 03/03

Summary of Contents for SB5400SS

Page 1: ...S MODEL RESIDENTIAL AND OUTDOOR FIREPLACE INSTALLATION OPERATION AND MAINTENANCE MANUAL THIS FIREPLACE IS LISTED BY OMNI TEST LABORATORIES FOR USE WITH L SERIES CHIMNEY SYSTEM COMPONENTS 53D9028 Rev 1...

Page 2: ...re to install operate and maintain this or any other factory built fireplace properly can result in a house fire or other occurrences that could cause deaths injuries and property damages It is very i...

Page 3: ...areas INTENDED PRODUCT USAGE The fireplace is designed to sit directly on a combustible floor The fireplace must be installed with clearances to combustible building materials specified in this manual...

Page 4: ...mper When the fireplace is not in use the damper should be closed to prevent cold air form entering the chimney as well as preventing warm air in the room from escaping up the chimney NOTE It is norma...

Page 5: ...30 ELBOWS 21 FT MN HEIGHT 4 30 ELBOWS 86FT MAX HEIGHT CHIMNEY SUPPORT EVERY 25 FT FIRESTOP MODEL LF FS 2 REQUIRES 17x17 FRAMING 54 STORM COLLAR MODEL LC CHIMNEY CAP ROOF FLASHING MODEL 612 CAUTION DO...

Page 6: ...DOORS ARE INSTALLED APPLIES WHEN GLASS DOORS ARE INSTALLED SAMPLE INSTALLATION FOR REFERENCE ONLY EXTERIOR FINISH MATERIALS REMOVED FOR CLARITY FIGURE 2 TOP EDGE OF FIREPLA OP EDGE OF FIREPLACE CE CO...

Page 7: ...6 L 3 6 L 4 8 L 1 8 L 1 8 L 3 6 39 5 16 76 11 16 L SERIES CHIMNEY SECTIONS 47 5 8 47 L48 35 5 8 35 17 5 8 17 11 5 8 11 L18 L36 L12 L18 L18 34 5 8 34 LINEAR GAIN L18 L36 52 LINEAR GAIN 52 5 8 L36 L36...

Page 8: ...and some suggested fireplace locations When selecting a location choose one that is away from frequently opened doors central heat outlets or returns or other places where air movements may disturb t...

Page 9: ...ments under or near trees or above the roof of a single story wing of a two story building as shown by Figure 9 All these conditions can cause turbulence or pressure conditions that can cause poor chi...

Page 10: ...EIGHT STORM COLLAR FLASHING 612 OR 1212 LC CHIMNEY CAP FIRESTOP SPACER LF FS 2 2 AIR SPACE CLEARANCE TO COMBUSTIBLES 17 SQUARE OPENING IN JOIST 17 SQUARE OPENING IN JOIST 612 OR 1212 FLUE OUTLET HEIGH...

Page 11: ...ng on it and insulating qualities equal to or better than the 1 2 covering provided by the H2068 20 MIN 6 MIN 12 MIN 12 MIN BRICK OR STONE HEARTH EXTENSION 68 LONG MIN SAFETY STRIP IS REQUIRED WHEN UN...

Page 12: ...o another is as follows C K divided by the material thickness Example C 43 divided by 1 2 50 C 86 K C multiplies by the material thickness Example K 86 multiplied by 1 2 50 K 43 R The material thickne...

Page 13: ...l 17 inch firestop spacer One required at each ceiling or floor level 6 12 12 12 pitch flashing for contemporary installation 6 12 12 12 pitch flashing for contemporary installation 0 6 12 pitch flash...

Page 14: ...fireplace and chimney CHIMNEY INSTALLATION In order to assure safe and satisfactory performance of the fireplace it is very important to properly install the chimney This is an important part of the...

Page 15: ...the snap locks engage Continue the process adding the chimney sections on top of each other until the chimney is at least six inches above the roof opening on all sided As the chimney sections are in...

Page 16: ...1 12 2 12 3 12 4 12 5 12 6 12 7 12 8 12 9 12 10 12 11 12 12 12 INSTALLATION OF FIRESTOP SPACER AT FLOOR LEVELS INSTALLATION OF FIRESTOP SPACER AT FLOOR LEVELS INSTALLATION OF FIRESTOP SPACER AT ATTIC...

Page 17: ...to the chimney at the extremities of the offset It is recommended that enclosing material not follow the inclined portions of the chimney OFFSET INSTALLATION SEQUENCE 1 Determine the location and amou...

Page 18: ...HIMN CLEARANCE AT JOIST L SERIES CHIMNEY CONTINUE CHIMNEY THROUGH ROOF AN CONTINUE CHIMNEY THROUGH ROOF AND INSTALL ROUND CHIMNEY CAP OR CHIMNEY HOUSING FIRESTOP SPACER DIAGONAL CHIMNEY ENCLOSURE RISE...

Page 19: ...he flashing over the chimney Adjust the chimney to assure that the proper minimum clearances are maintained 5 Nail the flashing securely in place with eight nails 6 Seal the crack between the top of t...

Page 20: ...SET 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 INTERMEDIATE INTERMEDIATE SECTIONS S...

Page 21: ...flue pipe and lower it down until the 3 cap legs rest on the top edge of the outer telescope pipe Secure legs of cap to the telescope with screws provided 7 Check all parts of the chimney and chimney...

Page 22: ...NST FIREBOX WALL AND GASKET STEP 1 SECURE OUTSIDE AIR STARTING COLLAR TO LEFT SIDE OF FIREPLACE WITH FOUR SHEET METAL SCREWS PROVIDED NOTE THE STARTING COLLAR EXTENDS THROUGH THE OUTER FIREPLACE JACKE...

Page 23: ...he assembly should be located above the snow line to prevent blockage by snow accumulation 3 The combustion air inlet assembly should never be mounted in a garage or storage area where combustible fum...

Page 24: ...of the wall to which the AK 4 inlet air vent will be attached The duct may be cut with a standard pocket knife use FP 4 U duct for maximum efficiency and safety Do not use a combustible duct Always us...

Page 25: ...1 11 2 unvented room heater is installed in this fireplace a H2853 CANOPY must also be installed WARNING Do not operate an unvented gas log set in this fireplace with the chimney removed The installer...

Page 26: ...the fireplace face Seal the face of the fireplace to the surrounding wall with non combustible caulk or trim materials to prevent cold air leakage around the fireplace The trim should not block or res...

Page 27: ...E MANTEL USTIBLE MANTEL USE ONLY NON COMBUSTIBLE MATERIALS BELOW W TOP OF SPACERS COMBUSTIBLE FRAMING MEMBERS TO TOP OF SPACERS 12 MAX MAX 18 MIN FROM FIREPLACE OPENING TO BOTTOM OF COMBUSTIBLE MANTEL...

Page 28: ...a little combined with other wood goes a long way Start your fire with a mixture of softwood and hardwood then add some fruit or nut wood for nostalgic aroma Since most woods will not burn well when...

Page 29: ...s doors close them DO NOT LEAVE CHILDREN OR PHYSICALLY OR MENTALLY HANDICAPPED OR SENILE PERSONS ALONE WITH A BURNING FIREPLACE You ll need a minimum of three logs preferably four to make a good fire...

Page 30: ...reosote buildup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire The chimney cap can be removed for inspection maintenance and cleaning by removing th...

Page 31: ...f the fireplace 4 Do insulate the exterior walls surrounding the fireplace to prevent excessive heat loss from the fireplace 5 Do trim the face of the fireplace only with noncombustible materials 6 Do...

Page 32: ...articles near the fireplace 15 Don t store or place flammable liquids gases or pressurized containers near the fireplace 16 Don t neglect to instruct all responsible persons in the proper and safe op...

Page 33: ...R FIREBRICK BACK ASSEMBLY FIREBRICK RT SIDE ASSEMBLY HEARTH REFRACTORY KEY NO 1 2 3 4 5 6 7 8 9 10 FIGURE 28 53D9028 Rev 1 03 03 All repair part orders should be placed through your local dealer To en...

Page 34: ...onents Cracks in ceramic and castable parts that do not affect safe operation We do not warrant this fireplace to be in compliance with your local building code Building codes vary greatly throughout...

Page 35: ...Contact the nearest dealer If you cannot locate your dealer call or write Martin Hearth Heating as indicated below 2 If you do not receive satisfactory service from the dealer within a reasonable time...

Page 36: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FOR CONSUMER USE 53D9028 REV 1 03 03...