background image

C

HIMNEY

  O

FFSET

  I

NSTALLATION

16

E

LBOW

 I

NSTALLATION

The following are important points that should be observed when installing elbows on the fireplace:

1. The support straps of all elbows not installed directly on top of the fireplace should be nailed securely to the

surrounding structure.  This allows the support strap to carry the weight of the chimney above the elbow
and prevents this weight from breaking the elbow or chimney sections apart.

2. Elbows should not be used in any combination that inclines the chimney more than 30 degrees from vertical.

3. The limitations on the quantity of elbows per chimney are as follows: If the total height of the fireplace and

chimney is—12' - 2" or more — two elbows may be used in the chimney.  21' - 0" or more — four elbows
may be used in the chimney.

4. The inclined portions of chimneys that pass through living spaces likely to be used for storage should be

enclosed to avoid contact with and possible damage to the chimney.  The minimum air space of two inches
between the chimney and enclosing materials must be maintained.

5. The length of the inclined portion of chimney between elbows must not exceed 6 feet when unsupported or

20 feet if the chimney is supported at six-foot intervals with support such as metal support straps.

6. When enclosing the elbows and inclined portions of the chimney, enclosing materials must be installed

vertically to maintain the required two-inch minimum air space clearance to the chimney at the extremities
of the offset.  It is recommended that enclosing material not follow the inclined portions of the chimney.

O

FFSET

 I

NSTALLATION

 S

EQUENCE

1. Determine the location and amount of offset required, then select the combinations of chimney sections

and elbows required from the offset chart.  Refer to Page 19.

2. Install the first LE30 elbow by placing the extended flue into the mating part of the fireplace or chimney

section.  Push down until the outside or inlet air duct of the elbow overlaps and the snaps lock the elbow into
the fireplace or chimney section.

3. Nail the support straps to the framing member with a minimum of two 8-penny nails per strap.

4. Install the sections of pipe between elbows until the proper number of chimney sections have been installed.

5. Install the second elbow to return the run of the chimney to vertical.

6. Nail the support straps of the second elbow to a building frame member.

7. Continue installing the vertical portion of the chimney.

NOTE:  If the inclined portion of the chimney passes through a floor or ceiling, an LF-FS-30 firestop spacer
should be installed to provide the firestop and support required.  Be sure proper spacing in maintained between
the chimney and combustibles.

FLUE PIPE

INLET AIR PIPE

30˚ ELBOW

ALL FOUR SUPPORT
STRAPS MUST BE NAILED
ON TO FRAMING MEMBER
AROUND THE ELBOW WITH 
A MINIMUM OF TWO (2)
8-PENNY NAILS PER STRAP

NOTE:
ALTHOUGH BOTH HALVES OF 
THE ELBOW SET MAY HAVE
TIE STRAPS, ONLY THE TOP
HALF MUST BE SECURED. THE
BOTTOM ELBOW HALF IS NOT
REQUIRED TO BE SECURED FOR

REQUIRED TO BE SECURED FOR
ADDED STABILIZATION OF PIPE  

F

IGURE

 20

53D9028. Rev 1 03/03

Summary of Contents for SB5400SS

Page 1: ...S MODEL RESIDENTIAL AND OUTDOOR FIREPLACE INSTALLATION OPERATION AND MAINTENANCE MANUAL THIS FIREPLACE IS LISTED BY OMNI TEST LABORATORIES FOR USE WITH L SERIES CHIMNEY SYSTEM COMPONENTS 53D9028 Rev 1...

Page 2: ...re to install operate and maintain this or any other factory built fireplace properly can result in a house fire or other occurrences that could cause deaths injuries and property damages It is very i...

Page 3: ...areas INTENDED PRODUCT USAGE The fireplace is designed to sit directly on a combustible floor The fireplace must be installed with clearances to combustible building materials specified in this manual...

Page 4: ...mper When the fireplace is not in use the damper should be closed to prevent cold air form entering the chimney as well as preventing warm air in the room from escaping up the chimney NOTE It is norma...

Page 5: ...30 ELBOWS 21 FT MN HEIGHT 4 30 ELBOWS 86FT MAX HEIGHT CHIMNEY SUPPORT EVERY 25 FT FIRESTOP MODEL LF FS 2 REQUIRES 17x17 FRAMING 54 STORM COLLAR MODEL LC CHIMNEY CAP ROOF FLASHING MODEL 612 CAUTION DO...

Page 6: ...DOORS ARE INSTALLED APPLIES WHEN GLASS DOORS ARE INSTALLED SAMPLE INSTALLATION FOR REFERENCE ONLY EXTERIOR FINISH MATERIALS REMOVED FOR CLARITY FIGURE 2 TOP EDGE OF FIREPLA OP EDGE OF FIREPLACE CE CO...

Page 7: ...6 L 3 6 L 4 8 L 1 8 L 1 8 L 3 6 39 5 16 76 11 16 L SERIES CHIMNEY SECTIONS 47 5 8 47 L48 35 5 8 35 17 5 8 17 11 5 8 11 L18 L36 L12 L18 L18 34 5 8 34 LINEAR GAIN L18 L36 52 LINEAR GAIN 52 5 8 L36 L36...

Page 8: ...and some suggested fireplace locations When selecting a location choose one that is away from frequently opened doors central heat outlets or returns or other places where air movements may disturb t...

Page 9: ...ments under or near trees or above the roof of a single story wing of a two story building as shown by Figure 9 All these conditions can cause turbulence or pressure conditions that can cause poor chi...

Page 10: ...EIGHT STORM COLLAR FLASHING 612 OR 1212 LC CHIMNEY CAP FIRESTOP SPACER LF FS 2 2 AIR SPACE CLEARANCE TO COMBUSTIBLES 17 SQUARE OPENING IN JOIST 17 SQUARE OPENING IN JOIST 612 OR 1212 FLUE OUTLET HEIGH...

Page 11: ...ng on it and insulating qualities equal to or better than the 1 2 covering provided by the H2068 20 MIN 6 MIN 12 MIN 12 MIN BRICK OR STONE HEARTH EXTENSION 68 LONG MIN SAFETY STRIP IS REQUIRED WHEN UN...

Page 12: ...o another is as follows C K divided by the material thickness Example C 43 divided by 1 2 50 C 86 K C multiplies by the material thickness Example K 86 multiplied by 1 2 50 K 43 R The material thickne...

Page 13: ...l 17 inch firestop spacer One required at each ceiling or floor level 6 12 12 12 pitch flashing for contemporary installation 6 12 12 12 pitch flashing for contemporary installation 0 6 12 pitch flash...

Page 14: ...fireplace and chimney CHIMNEY INSTALLATION In order to assure safe and satisfactory performance of the fireplace it is very important to properly install the chimney This is an important part of the...

Page 15: ...the snap locks engage Continue the process adding the chimney sections on top of each other until the chimney is at least six inches above the roof opening on all sided As the chimney sections are in...

Page 16: ...1 12 2 12 3 12 4 12 5 12 6 12 7 12 8 12 9 12 10 12 11 12 12 12 INSTALLATION OF FIRESTOP SPACER AT FLOOR LEVELS INSTALLATION OF FIRESTOP SPACER AT FLOOR LEVELS INSTALLATION OF FIRESTOP SPACER AT ATTIC...

Page 17: ...to the chimney at the extremities of the offset It is recommended that enclosing material not follow the inclined portions of the chimney OFFSET INSTALLATION SEQUENCE 1 Determine the location and amou...

Page 18: ...HIMN CLEARANCE AT JOIST L SERIES CHIMNEY CONTINUE CHIMNEY THROUGH ROOF AN CONTINUE CHIMNEY THROUGH ROOF AND INSTALL ROUND CHIMNEY CAP OR CHIMNEY HOUSING FIRESTOP SPACER DIAGONAL CHIMNEY ENCLOSURE RISE...

Page 19: ...he flashing over the chimney Adjust the chimney to assure that the proper minimum clearances are maintained 5 Nail the flashing securely in place with eight nails 6 Seal the crack between the top of t...

Page 20: ...SET 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 INTERMEDIATE INTERMEDIATE SECTIONS S...

Page 21: ...flue pipe and lower it down until the 3 cap legs rest on the top edge of the outer telescope pipe Secure legs of cap to the telescope with screws provided 7 Check all parts of the chimney and chimney...

Page 22: ...NST FIREBOX WALL AND GASKET STEP 1 SECURE OUTSIDE AIR STARTING COLLAR TO LEFT SIDE OF FIREPLACE WITH FOUR SHEET METAL SCREWS PROVIDED NOTE THE STARTING COLLAR EXTENDS THROUGH THE OUTER FIREPLACE JACKE...

Page 23: ...he assembly should be located above the snow line to prevent blockage by snow accumulation 3 The combustion air inlet assembly should never be mounted in a garage or storage area where combustible fum...

Page 24: ...of the wall to which the AK 4 inlet air vent will be attached The duct may be cut with a standard pocket knife use FP 4 U duct for maximum efficiency and safety Do not use a combustible duct Always us...

Page 25: ...1 11 2 unvented room heater is installed in this fireplace a H2853 CANOPY must also be installed WARNING Do not operate an unvented gas log set in this fireplace with the chimney removed The installer...

Page 26: ...the fireplace face Seal the face of the fireplace to the surrounding wall with non combustible caulk or trim materials to prevent cold air leakage around the fireplace The trim should not block or res...

Page 27: ...E MANTEL USTIBLE MANTEL USE ONLY NON COMBUSTIBLE MATERIALS BELOW W TOP OF SPACERS COMBUSTIBLE FRAMING MEMBERS TO TOP OF SPACERS 12 MAX MAX 18 MIN FROM FIREPLACE OPENING TO BOTTOM OF COMBUSTIBLE MANTEL...

Page 28: ...a little combined with other wood goes a long way Start your fire with a mixture of softwood and hardwood then add some fruit or nut wood for nostalgic aroma Since most woods will not burn well when...

Page 29: ...s doors close them DO NOT LEAVE CHILDREN OR PHYSICALLY OR MENTALLY HANDICAPPED OR SENILE PERSONS ALONE WITH A BURNING FIREPLACE You ll need a minimum of three logs preferably four to make a good fire...

Page 30: ...reosote buildup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire The chimney cap can be removed for inspection maintenance and cleaning by removing th...

Page 31: ...f the fireplace 4 Do insulate the exterior walls surrounding the fireplace to prevent excessive heat loss from the fireplace 5 Do trim the face of the fireplace only with noncombustible materials 6 Do...

Page 32: ...articles near the fireplace 15 Don t store or place flammable liquids gases or pressurized containers near the fireplace 16 Don t neglect to instruct all responsible persons in the proper and safe op...

Page 33: ...R FIREBRICK BACK ASSEMBLY FIREBRICK RT SIDE ASSEMBLY HEARTH REFRACTORY KEY NO 1 2 3 4 5 6 7 8 9 10 FIGURE 28 53D9028 Rev 1 03 03 All repair part orders should be placed through your local dealer To en...

Page 34: ...onents Cracks in ceramic and castable parts that do not affect safe operation We do not warrant this fireplace to be in compliance with your local building code Building codes vary greatly throughout...

Page 35: ...Contact the nearest dealer If you cannot locate your dealer call or write Martin Hearth Heating as indicated below 2 If you do not receive satisfactory service from the dealer within a reasonable time...

Page 36: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FOR CONSUMER USE 53D9028 REV 1 03 03...

Reviews: