© Martin Engineering GmbH
31
M3814UK-03/16
Troubleshooting
Bent or broken
mainframe due to the
cleaner blade slipping
through.
Cleaner blade at or beyond
the wear limit.
Replace the cleaner blade.
Main shaft incorrectly
positioned.
Check the position of the main
shaft and correct if necessary.
Noises or vibrations.
The scraper is fixed either
too loosely or too tightly
against the conveyor belt.
Adjust the tension if necessary.
The urethane of the cleaner
blade may not be suitable
for the application.
Contact Martin Engineering or an
authorised dealer.
Corrosion or chemical
degradation.
The urethane of the cleaner
blade may not be suitable
for the application.
Contact Martin Engineering or an
authorised dealer.
Symptom
Cause
Corrective action
Tab. 5: Troubleshooting