52
MAC III AirFX user manual
SERVICE
PAN/TILT
FEEDBACK
On
Enable pan/tilt position feedback
systems
Off
Disable pan/tilt position feedback
ADJUST
PAN/TILT
SENSOR
CALIBRATION
PAN/TILT AT
END STOP
Move pan and tilt to end stops following
instructions in the display, then execute to
calibrate pan and tilt sensors
CMY MODULE
DIMMER
For use by qualified service technicians –
see Martin service documentation before
entering this menu
EFFECT MODULE
SHUTTER
PAN/TILT
MODULE
PAN
TILT
CALIBRATION
DIMMER ... TILT
Set individual effects to calibration
positions (approx. +/- 5% offset available)
LOAD DEFAULTS?
Load factory default calibration settings
SAVE FACTORY DEFAULT?
Replace factory default calibration settings
with current calibration settings
UPDATE
FIRMWARE
UPDATE
Execute to update fixture firmware from
bank shown in display
BANK
Firmware bank version
LOCATION
Location of firmware bank
EVENT LOG
EVENT LOG TRIGGER
Triggers generation of event log
CLEAN EVENT LOG
Clears event log and any current errors
Menu level 1
Menu level 2
Menu level 3
Menu level 4
Notes (Default settings in bold print)
Table 3: Control menus
Summary of Contents for MAC III AirFX
Page 1: ...MAC III AirFX USER MANUAL...
Page 62: ......