54
MAC III AirFX user manual
CDZF
CALIBRATE DATA ZOOM/FOCUS
Unable to read/write data to external eeprom board (Calibrate Data) on Zoom/Focus module. The
cables need to be checked or the module may need to be replaced.
CECH
COM ERROR CHARGER
I2C communication between main controller and charger failed. The cables need to be checked or
the module may need to be replaced.
CECM
COM ERROR CMY
CAN communication between main controller and CMY driver failed. The cables need to be
checked or the driver may need to be replaced.
CECO
COM ERROR COOLING
CAN communication between main controller and cooling driver failed. The cables need to be
checked or the driver may need to be replaced.
CEEF
COM ERROR EFFECT
CAN communication between main controller and effects driver failed. The cables need to be
checked or the driver may need to be replaced.
CELF
CLEAN EVENT LOG FAILED
CEPT
COM ERROR PAN/TILT
CAN communication between main controller and pan/tilt driver failed. The cables need to be
checked or the driver may need to be replaced.
CEPU
COM ERROR POWER UNIT
I2C communication between main controller and ballast failed. The cables need to be checked or
the module may need to be replaced.
CEUI
COM ERROR UI
User interface communication failure. The cables need to be checked or the module may need to be
replaced.
CEZF
COM ERROR ZOOM/FOCUS
CAN communication between main controller and zoom/focus driver failed. The cables need to be
checked or the driver may need to be replaced.
COLD
FIXTURE IS COLD
PCBs are below -20° C (-4° F)
CONC
COOLING NO CONNECTION
(s/w versions prior to ver. 1.3)
CONE
EFFECT NO CONNECTION
(s/w versions prior to ver. 1.3)
CONM
CMY NO CONNECTION
(s/w versions prior to ver. 1.3)
CONP
PAN/TILT NO CONNECTION
(s/w versions prior to ver. 1.3)
CONZ
ZOOM/FOCUS NO CONNECTION
(s/w versions prior to ver. 1.3)
CTER
CTC ERROR
The sensors, wiring and motor need to be checked and the driver PCB may need to be replaced.
CYER
CYAN ERROR
The sensors, wiring and motor need to be checked and the driver PCB may need to be replaced.
DIER
DIMMER ERROR
The sensors, wiring and motor need to be checked and the driver PCB may need to be replaced.
DINA
DIMMER NOT ADJUSTED
Dimmers need to be adjusted by a qualified service technician.
ECDE
EFFECT CALIBRATE DATA PCB
(s/w versions prior to ver. 1.3)
Unable to read/write data to external EEPROM board (calibrate date) on effect module
EEDF
WRITING EEPROM DEFAULT(S)
No valid EEPROM in a CAN module. Writing default into the EEPROM based on the CAN address.
Module is possibly incorrectly connected
EEPR
EEPROM INVALID/NO CONN.
No connection or EEPROM data invalid
EFSM
ERROR FAILSAFE MODE
Module error detected during self-check at startup. Service intervention required. Fixture control
possibly disabled, depending on nature of error.
FAN
LAMP R FAN ERROR
FAN
LAMP L FAN ERROR
FAN
BOTTOM FAN ERROR
Short code
Full-text message
Table 5: Error messages