18
0$&(
3.
Plug in any unplugged connectors, apply power to the MAC 600/E, and proceed with the upload.
4.
After the upload, disconnect the fixture from the electricity, move the jumper back to the normal setting, and replace
the circuit board.
a p p e n d i x a
DMX PROTOCOL
DMX channel
Start code = 0
DMX1
DMX2
DMX3
DMX4
Value
Percent
Function
1
Note:
Lamp
Off
is
allowed
with
SPEC/dLoF set to ON, or with
SPEC/dLoF set to OFF and cyan,
magenta and yellow set between
230 and 232.
Reset is allowed with SPEC/dRES
set to ON, or with SPEC/dRES set
to OFF and cyan, magenta and
yellow set between 230 and 232.
0 - 19
20 - 49
50 -
112
113 -
115
116 -
122
123 -
127
128 -
147
148 -
167
168 -
187
188 -
207
208 -
217
218 -
227
228 -
237
238 -
247
248 -
255
0 - 7
8 - 19
20 - 44
44 - 45
45 - 48
48 - 50
50 - 58
58 - 65
66 - 73
74 - 81
82 - 85
85 - 89
89 - 93
93 - 97
97 - 100
6KXWWHU6WUREH5HVHW/DPS2Q2II
Shutter closed
Shutter open
Strobe on (fast->slow)
Shutter closed
Shutter open, reduced lamp power (MAC 600 E)
Shutter closed
Random Strobe Fast
Random Strobe Medium
Random Strobe Slow
Shutter closed Reset
Fixture
Shutter closed
Lamp power on
Shutter closed
Lamp power off 1RWH: T
≥
5 seconds
2
0 - 255
0 - 100
,QWHQVLW\
0
100%
3
0-255
0 - 100
&\DQ
White
Cyan
4
0-255
0 - 100
0DJHQWD
White
Magenta
5
0-255
0 - 100
<HOORZ
White
Yellow