0$&(
Pan/tilt feedback
SPEC/FEbA
ON
Enable pan/tilt position correction system.
OFF
Disable pan/tilt feedback. Setting not saved.
Effects feedback
SPEC/EFFb
ON
Enable feedback on effect wheels.
OFF
Disable feedback on
effect wheels.
Fan speed
SPEC/FAN
REG
Enable automatic fan speed regulation.
FULL
Set fan speed to full.
Electronic ballast
type
SPEC/ETYP
SCHI
Select Schiederwerk ballast (MAC 600 E's after S/N
4020700000)
MITR
Select Mitronic ballast (MAC 600 E’s with date-based S/N or
before S/N 4020700000)
* Setting may be overridden via DMX. See the protocol for details.
Readouts
U s a g e r e a d o u t s (
TIME
)
Read the total number of power-on hours (
Po
H
), power-on hours since last reset (
RPoH
), total lamp hours (
LA
H
), lamp hours since
last reset (
RLAH
), total number of lamp strikes (
LSTR
), and the number of lamp strikes since last reset (
RLST
).
The resettable counters may be used to track overall usage and lamp life. To reset to zero, display the readout and then press
[
↑
]
for 5
seconds.
D M X v a l u e r e a d o u t s (
dMXL
)
Read the DMX start code (
STCO
) and DMX values received for each channel. This is an easy way to check that the start code is 0 and
that the fixture is receiving the expected commands.
If the fixture is set to a DMX mode where some or all of the channels between 10 and 13 are not used, the readout on these channels
will be
N/A
. Note: the channel number is 1 less in the readout than it is in the DMX protocol.
S o f t w a r e v e r s i o n r e a d o u t s (
VER
)
Read the version number of the CPU software (
CPU
), pan/tilt feedback circuit (
FEbA
), and display module software (
dISP
). The
CPU software version is also displayed for a moment at power up.
Te m p e r a t u r e r e a d o u t s (
SPEC
/
TEMP
)
Read temperature in the base (
bASE
) and head (
HEAd
) in Celsius. Temperatures below 25° C are shown as
-25
; temperatures above
100° C are shown as
+100
.
Thetemperature sensors are calibrated at the factory and adjustment should not be necessary. The following procedure calibrates the
sensors if they give no or faulty readings.
1.
Allow the unit to cool to room temperature (powered off for at least 4 hours).
2.
Measure the room temperature in Celsius. (To convert F° to C°, subtract 32° and then multiply by
0.555.)
3.
Power up the unit and allow it to reset.
4.
Press the [MENU] and [
↓
] keys at the same time and hold them for 3 seconds until “25” shows in the display.
5.
Press the
[↑
] and [
↓
] keys until the display shows the temperature measured.
6.
Press [ENTER] to save the setting.