User Manual 13
Manual control
M a n u a l c o n t r o l (
MAN
)
The manual control menu permits you to do the following without a controller:
•
reset the fixture (
RST
)
•
turn the lamp on and off (
L ON
,
LoFF
)
•
open, close, and strobe the shutter at 3 speeds (
SHUT
)
•
control the dimmer (
dIM
)
•
control the CMY wheels (
CYAN, YEL, MAG
)
•
move the color wheel to each position (
COL
)
•
control both beam shapers (
BS1, BS2
)
•
control pan and tilt (
PAN
,
TILT
)
A d j u s t m e n t (
AdJ
)
The adjustment menu provides manual control for making mechanical adjustments. These should only be performed by a qualified
technician. The menu provides functions to reset the fixture (
RST
), turn on and off the lamp (
L
ON
,
LoFF
), control all effects in the
head (HEAd), and move the head to the home and extreme positions (
PATI
). The
HEAd
submenu contains functions to:
•
move
ALL
effects to the
OPEN
,
SPOS
(sensor position), and
APOS
(adjustment position - requires special tool).
•
move each effect individually to the open, sensor, and adjustment positions. The shutter has a closed position instead of a sensor
position.
Test sequences
Te s t s e q u e n c e (
TSEQ
)
Run a general test of all effects.
P r i n t e d c i r c u i t b o a r d t e s t (
SPEC/PCBT
)
3 tests of the circuit board for service use.
F a c t o r y t e s t (
SPEC/FTST
)
An effects test (
WTST
), a movement test (
MTST
), and a sensor test (
STST
) used for factory quality control. The sensor test includes
programs for testing sensors on the effect wheels.
Utilities
C a l i b r a t i o n (
CAL
)
The calibration menu allows you to adjust the effects to achieve total uniformity between fixtures: it is not a substitute for mechanical
adjustment. Pan (
P OF
), tilt (
T OF
), dimmer (
d OF
), cyan (
C OF
), magenta (
M OF
), and yellow (
Y OF
) may be selected and
adjusted from 1 to 255 with the arrow keys. Press
[
ENTER
]
to save the calibration.
R e s e t d e f a u l t o f f s e t s (
SPEC/dFOF
)
Reset all calibrations to their factory defaults. Select
dFOF
and press [ENTER] when
SURE
is displayed, or press
[
MENU
]
to escape.
R e s e t d e f a u l t p e r s o n a l i t y s e t t i n g s (
SPEC
/
dFSE
/
FACT
)
Return all personality settings (not calibrations) to their factory defaults. Select
FACT
and press [ENTER] when
LOAD
is displayed.
C u s t o m c o n f i g u r a t i o n s (
SPEC
/
dFSE
/
CUS1
,
CUS2
,
CUS3
)
Save and load 3 sets of custom configurations. To save a custom configuration, adjust the settings as desired, go to
CUS1
,
CUS2
, or
CUS3
and press [ENTER] when
SAVE
is displayed. To load a custom setting, select it and press [ENTER] when
LOAD