Physical installation 

 

Warning! Read ‘Safety information’ on page 5 before installing the fixture. 

Warning! The safety and suitability of lifting equipment, installation location, anchoring 
method, mounting hardware and electrical installation are the responsibility of the installer. 
All local safety regulations and legal requirements must be observed when installing and 
connecting the Exterior Wash

 200 Series. Installation must be carried out by qualified 

professionals only.  

Contact your Martin supplier for assistance if you have any questions about how to install this product 
safely. 

Fixture location 

Exterior Wash

 200 Series fixtures are intended for outdoor use. With an IP rating of 66, they are dust 

tight and able to withstand powerful water jets, but they are not submersible.  

Observe the following limitations in selecting a location:  

 

Do not immerse the fixture in water or any other fluid. 

 

Do not install fixtures in a location where flooding may occur. 

 

Do not allow water to collect on or near the pressure relief valve. Do not install a fixture with the valve 
membrane horizontal so that water can pool on it. 

 

Ensure sufficient drainage to cope with the heaviest rainfall. Make sure that water can drain away from the 
installation area at least as fast as it can enter it. 

 

Fixtures require free and unobstructed airflow around them to ensure adequate cooling: do not bury or 
locate in an unventilated space. Allow at least 0.1 m (4 in.) free space around the fixture. 

 

Install the fixture at least 0.2 m (8 in.) away from the surface to be illuminated and at least 0.1 m (4 in.) 
away from any combustible materials (wood, paper, etc.). Keep it well away from any flammable materials. 

 

The fixture can become hot. Restrict public access or locate the fixture so that it cannot accidentally be 
touched. 

Mounting the fixture 

 

Warning! All fasteners used to mount Exterior Wash

 200 Series 

fixtures must be corrosion resistant and strong enough to mount 
the fixture safely.  

A washer must be installed directly under the head of each fastener 
when anchoring the yoke base to the installation surface. 

The fixture and mounting bracket are manufactured in corrosion-resistant anodized aluminum. Avoid 
mounting the fixture in direct contact with other types of metal, as this can cause galvanic corrosion. When 
fastening to a dissimilar metal surface: 

 

Use an electrically insulating material (such as rubber or plastic) or coating between the mounting bracket 
and the other metal. 

 

Use a non-conductive coating such as Delta Seal on fasteners (screws, bolts, washers, etc.) where they 
come into contact with the mounting bracket. 

The fixture

’s mounting yoke base must be securely anchored to a wall, pedestal, structural beam or other 

suitable support. The yoke allows the fixture to be manually panned and tilted for beam aiming adjustment. 

The fixture and base can be mounted at any angle. The mounting surface must be hard, fixed and flat.  

For temporary installations, the fixture is also suitable for truss hanging with a rigging clamp securely 
fastened to the yoke base. When using a rigging clamp, secure the fixture with a safety cable (or other 
secondary attachment) that is approved for the weight of the fixture so that the safety cable will hold the 
fixture if a primary attachment fails. Loop the safety cable through the attachment point on the back of the 
fixture. 

See ‘Fixture overview’ on page 9 for location.  

Fasten the fixture securely with suitable mechanical fasteners. Do not stand it on a surface or leave it 
where it can be moved or fall over. Ensure that the surface and all fasteners used can support at least 10 
times the weight of all fixtures and equipment they will support. 

Anchor the mounting yoke bracket to a flat surface. The number and type of fasteners used will depend on 
the installation, but use at least three high-strength corrosion-resistant fasteners (recommended minimum 

Summary of Contents for ExteriorWash 200 Series

Page 1: ......

Page 2: ...t loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual Martin Harman and all other trademarks in this...

Page 3: ...Connecting to power 13 Control data link 15 Connecting the data link 15 Setup 16 Accessing and navigating the control menus 16 DMX settings 16 Programming a standalone show 17 Manual mode 17 Display s...

Page 4: ......

Page 5: ...the safety precautions below are not followed Install operate and service Martin products only as directed in their user manuals or you may create a safety hazard or cause damage that is not covered b...

Page 6: ...the fixture Do not illuminate surfaces within 20 cm 8 in of the fixture Do not attempt to bypass thermostatic switches or fuses Do not modify the fixture in any way not described in this manual or in...

Page 7: ...on responses blink reflex and reaction to skin discomfort can protect them At distances greater than 2 2 m 7 3 ft potential eye and skin injury hazards from the light output are normally prevented by...

Page 8: ...attachment such as a safety cable inserted through the secondary attachment point that will hold the fixture if a primary attachment fails The secondary attachment must be approved by an official bod...

Page 9: ...access They are prepared for hard wiring with 1 8 m 5 9 ft cables for power and data connection Fixture overview Number Description 1 Front ring with recessed channel for optional diffuser lenses 2 Ti...

Page 10: ...ning All fasteners used to mount Exterior Wash 200 Series fixtures must be corrosion resistant and strong enough to mount the fixture safely A washer must be installed directly under the head of each...

Page 11: ...e fixture can become hot Wear heat resistant gloves if you adjust the aim of the fixture when it is or has recently been powered on Tilt adjustment can be carried out with the fixture powered on as fo...

Page 12: ...nt ring 4 Press the diffuser lens gasket firmly into the recess in the front ring 5 Either place a trim ring over the diffuser and fasten with provided hardware or install a snoot as described below A...

Page 13: ...0 Hz Do not connect to power at any other voltage or frequency You can connect the Exterior Wash 200 Series to a single phase live neutral ground earth or to one phase of a grounded earthed three phas...

Page 14: ...grounding type earthed plug with integral cable grip that is rated minimum 277 V 6 A Follow the plug manufacturer s instructions and connect the wires in the power cable as shown in this table Live or...

Page 15: ...ombined channel requirements of all connected fixtures exceeds 512 one or more additional DMX universes will be required One may reliably connect up to 32 fixtures in a single daisy chain Use RS 485 d...

Page 16: ...r Exterior Wash 210 channel mode from the control panel 1 Press and hold the MENU button to access the control menu If prompted for a password press the arrow buttons to scroll to the 3 digit password...

Page 17: ...press MENU again to return to the PROGRAM SHOW menu 4 To modify scene transitions select FADE TIME and press ENTER Press UP or DOWN to select a fade time from 0 to 120 seconds Press ENTER 5 To modify...

Page 18: ...red by the product warranty To operate fixtures in master slave mode the fixtures must be connected as described under Control data link on page 15 The master fixture must be programmed to run a stand...

Page 19: ...X signal or if the DMX signal is suddenly lost Note that for stand alone and master slave operation DMX STATE must be set to SHOW MODE SHOW MODE Fixture executes programmed scenes HOLD LAST LOOK Fixtu...

Page 20: ...YES and press ENTER to confirm or MENU to escape Setup via RDM The Exterior Wash 200 Series is compatible with RDM Remote Device Management Using an RDM compliant DMX controller you can communicate w...

Page 21: ...ce schedule Do not use products that contain solvents abrasives or caustic agents for cleaning as they can cause surface damage to the fixture The aluminum housing and front glass can be cleaned with...

Page 22: ...intensity on channel 1 Channel Value Function 1 0 255 Dimmer 0 100 2 0 255 Red 0 100 3 0 255 Green 0 100 4 0 255 Blue 0 100 5 0 255 White 0 100 Exterior Wash 220 The DMX protocol provides individual 0...

Page 23: ...ayed Manual Mode 200 210 Red 0 255 Manually adjust output Green 0 255 Blue 0 255 White 0 255 Manual Mode 220 Warm White 0 255 Manually adjust output Cold White 0 255 Display Setting Display Inverse No...

Page 24: ...fig contd DMX State Show Mode Behavior when no DMX control signal present Hold Last Look Black Out Display Lock No Yes Password protect control menu Lock Password 0 999 123 Set user password Factory R...

Page 25: ...nk defective Check number of DMX channels required by each fixture and check DMX addresses on fixtures and DMX controller Verify CHANNEL MODE setting Inspect connections and cables Correct poor connec...

Page 26: ...DM compliance ANSI ESTA E1 20 Exterior Wash 200 and 210 DMX channels 4 or 5 Exterior Wash 220 DMX channels 3 Optics All models Minimum LED lifetime 50 000 hours to 70 luminous output Figure obtained u...

Page 27: ...200 100 V 60 Hz 1 6 A 160 W PF 0 99 120 V 60 Hz 1 4 A 160 W PF 0 99 230 V 50 Hz 0 8 A 160 W PF 0 94 277 V 60 Hz 0 7 A 160 W PF 0 89 Exterior Wash 210 100 V 60 Hz 1 5 A 148 W PF 0 99 120 V 60 Hz 1 3 A...

Page 28: ...Exterior Wash 200 7 EU aluminum P N 90509087 Exterior Wash 200 7 US aluminum P N 90509090 Exterior Wash 210 10 EU aluminum P N 90509088 Exterior Wash 210 10 US aluminum P N 90509095 Exterior Wash 220...

Page 29: ...his product If it becomes difficult or impossible to read it must be replaced using the illustration below to reproduce a new label sized 58 x 16 mm in black with a yellow border RISK GROUP 3 WARNING...

Page 30: ...30 Exterior WashTM 200 Series User Manual...

Page 31: ......

Page 32: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Reviews: