background image

FIGURE 44

STEP 6 

      TESTING THE GARAGE DOOR OPENER SYSTEM

Press

 the push button to open door.  Observe that LED #5 

OPNG illuminates as the garage door opens.  The garage door 
will stop when it reaches the full open position allowed by the 
cable drums or optional bumper springs. Press the push button to 
close the door.  Observe that LED #4 CLSNG illuminates as the 
garage door closes.  The garage door will stop when it reaches 
the floor. If OPNG or CLSNG light does not go out when door 
stops, the belt tension may need to be adjusted (Max Power and 
Close Sensitivity may also need adjusting). See Figure 43

Open

 and close garage door two more complete cycles.  

Observe the movement of the garage door as the computer  
memorizes the open and close position.  You may notice that 
LED #1 ACK illuminates from time to time.  The garage door 
opener system now provides “soft  start” and “soft stop” as the 
door opens and closes. See Figure 43

Do Not

 touch the following settings unless you are sure.

Force Setting

: MAX POWER is factory set at one o’clock. Force 

can be slightly increased by turning screw clockwise 10 degrees 
at a time. See Figure 10b, 43

Sensitivity Setting

: CLOSE SENSITIVITY is factory set at one 

o’clock. Sensitivity can be increased by turning screw clockwise 
10 degrees at a time. See Figure 10b, 43 

Place

 a 1 1/2”(38) high object (or a 2X4 laid flat) on the floor, 

under the door. When the closing door contacts the object, it 
should stop, reverse, and automatically return to the open 
position. See Figure 44
If the door does not reverse, the drive belt may be slipping. After 
correcting drive belt tension and the door still does not reverse, 
call a trained Martin Door dealer. See Step 2

                                             

STEP 7

          INSERT INSTRUCTION MANUAL INTO PACKET

Fold and Insert 

instruction manual into the packet located on the 

#3 door section of the Martin garage door or mount to the wall.

An Important

 safety/instruction label is included with opener 

package. This label and the instruction manual must be fastened 
inside your garage where they can be easily seen. Fasten them 
next to the wall control box. Peel off the protective backing, and 
press onto smooth, clean surface. Tacks or additional adhesive 
may be necessary. DO NOT REMOVE OR PAINT OVER ANY 
LABELS.  See Figures 45, 46

COPYRIGHT © 2008 MARTIN DOOR

15

FIGURE 43

FIGURE 46      

!

8/2001

AD-01IM-03

INSTRUCTION  MANUAL

For all Residential Garage Doors up to 12’ (3700) High.

G

GARA E 

DOOR 

N

OPE ER 

S

IN TRUCTION

L

 

MANUA  AND

N

WARI NG 

L E

AB L

T

F

L

A

P

MAR IN  INGER SHIE D G RAGE DOOR AND O

ENER SYSTEM

 

S

A

           IN TRUCTION M NUALS AND WARNING LABEL

 

T

E

                        

(FAC ORY PACKAG D AND MOUNTED)

CONTROL

BOX

ASSEMBLY

AND PUSH

BUTTON

MOTOR ASSEMBLY

TM

DOOR OPENERS

ARTI

N

M

FIGURE 45     

      

A KET

 

  P C

(F

T

M

N E )

AC ORY  OU T D

L  

D

FO D AN  
IN

SER  

IN

UC

STR

TIO

MANU

 

AL

INTO

KET

 PAC

1 1/2”(38) HIGH OBJECT
FOR DOOR REVERSAL TEST 

Summary of Contents for DC4600

Page 1: ...tion manual features Low Risk Martin Finger Shield Garage Doors See page 7 for IMPORTANT INSTALLATION MAINTENANCE SAFETY INSTRUCTIONS MARTIN RESIDENTIAL TORSION DRIVE OPENER R E M G R I I S F T D E E...

Page 2: ...to 9b and Step 2 Emergency Release Lever with Bracket Bowden Cable with Cable Post and D Shackle Screw Hook with Lock Nut Chain Extension Package Control Box Assembly See Figures 10a 10b and Step 3 C...

Page 3: ...T MOTOR COVER BACK MOT R O VER CO MOTOR PULLEY ANTI TORQUE ARM SPACER HEX HEAD BOLT BACK MOTOR COVER SMALL CLIPS BACK PLATE DRIVE BELT TENSIONING PLATE DRIVE BELT TORSION SHAFT PULLEY MOTOR COVER SCRE...

Page 4: ...G BOWDEN CABLE HAS SLACK HIGH LIFT OR VERTICAL LIFT TRACK LAG SCREWS EMERGENCY RELEASE LEVER SCREW HOOK ON D SHACKLE EMERGENCY RELEASE LEVER SCREW HOOK ON EXTENSION CHAIN REVERSE ANGLE SHIELD LOCK NUT...

Page 5: ...V RLY GND Red G r e n e h t W i e B lu e AUTO MOTOR POLARITY STOP BUTTON O RIDE SAFETY MODE 1 The open limit is set automatically as the garage door reaches opened position allowed by the cable drums...

Page 6: ...A qualified electrician should install a grounded electrical outlet within 5 1520 of the Control Box Assembly location according to local codes See Figure 1 Make sure the garage door is properly balan...

Page 7: ...in sight of door at min height of 5 1520 so small children cannot reach it and away from all moving parts of door Emergency release lever should be installed and adjusted to about 6 1830 above the flo...

Page 8: ...back plate of the motor assembly with the 10mm hex head bolt and 1 2 13 spacer Fasten the 10mm hex head bolt and 1 2 13 spacer through the back motor cover into the back plate of the motor assembly S...

Page 9: ...tening the drive belt on the motor and torsion shaft pulley The garage door opener will not function without proper drive belt tension The computer cannot learn if drive belt slips Pushing the emergen...

Page 10: ...r other means See Figures 23 24 Temporarily fasten the control box lid to the left or right side above or below the control box to prevent it from hanging by the push button wires during the setup pro...

Page 11: ...lt Photo eye Off On for photo eyes etc Sw4 Auto Close Off N A in North America Sw5 Inter Lock Over Ride On Off for inter lock lock out switch Sw6 Lighting Mode Off On eliminates light delay timer Sw7...

Page 12: ...a calibration reset with the door closed Calibration Reset Press and hold reset button Press and hold program button Release reset button Wait and observe that the L E D 1ACK blinks Release Program B...

Page 13: ...utton Antenna The 315 MHZ receiver antenna wire on the radio receiver is about 13 340 long and can have multiple arrangements for the best distance In a normal installation the distance from the trans...

Page 14: ...ible Follow instructions furnished in the automobile owners manual for non rolling code applications TRANSMITTER OPERATION Press button until garage door begins to move The indicator light on the tran...

Page 15: ...1 2 38 high object or a 2X4 laid flat on the floor under the door When the closing door contacts the object it should stop reverse and automatically return to the open position See Figure 44 If the do...

Page 16: ...or increases the risk of severe injury or death Call a trained Martin Door Dealer to repair lift cables spring assemblies and other hardware TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ AND FOLLO...

Page 17: ...t in the external circuit DIP switch No 1 should be set to ON which is the position marked RES for resistive If the safety circuit is interrupted while the door is operating with the auto close DIP sw...

Page 18: ...but now doesn t increase the closing force and or reduce the sensitivity After adjustment Is completed repeat the tests See STEP 4 and 6 Maybe springs are wound too tight Tighten drive belt Call a Ma...

Page 19: ...Door Height 15 4600 Height W idth Depth Pow er 5 0 130 beyond the lock on side bearing bracket Drive V Belt Approximate W eight Plus Packaging Automatic Standard in the down run cycle Model For option...

Page 20: ...e open section joints inside and outside Exposed holes in tracks larger than 1 4 7 Exposed track brackets fastening vertical tracks to jambs Exposed outside lift cables Exposed rollers moving in verti...

Reviews: