FIGURE 30
***STEP 3 CONTINUED***
The control box
assembly includes a 6’(1800) power cord with a
three prong plug. The third prong is ground. To reduce the risk of
electric shock do not alter or change plug or outlet in any way. Do not
try to conceal or staple the power cord or try to rout it through a door
way, window, wall, ceiling, floor, etc. The power cord must be routed
away from moving parts.
Also see “WARNING” On page 12.
Wait
until Step 4 before plugging the power cord into the grounded
electrical outlet.
DO NOT PINCH WIRING! The door opener will not work properly
with damaged wiring.
DIP Switch Positions. See Figure 10b, 30, 31
Observe
the factory set positions of each dip switch in the upper
right hand corner of the circuit board.
Sw1
Safety Mode
Off/Normally Closed
Sw2
Standard Safety Off (On for photo-eyes, etc.)
Sw3
12 Volt Photo-eye Off (On for photo-eyes, etc.)
Sw4
Auto Close
Off (N/A in North America)
Sw5
Inter-Lock Over-Ride On (Off for inter-lock lock-out switch)
Sw6
Lighting Mode Off (On eliminates light delay timer)
Sw7 Motor Polarity On/Off (as required)
Sw8 Stop Button Over-Ride On
See Figures 30, 31
COPYRIGHT © 2008 MARTIN DOOR
11
ACK = Acknowledge
SFTY = Safety
PWR = Power
CLSNG = Closing
OPNG = Opening
L.E.D. = Light Emitting Diode
Abbreviations
RLY = Relay
V = Volt
N = Neutral
COM = Common
GND = Ground
TX = Transmitter
RX = Receiver
FIGURE 31
ON APEMs
1 2 3 4 5 6 7 8
STD
SAFETY
12 V
PHOTO
EYE
I/LOCK
O/RIDE
LIGHT
MODE
N/C
AUTO
MOTOR
POLARITY
STOP
BUTTON
OVER-RIDE
SAFETY
MODE
***CLEARING SERVICE DUE REMINDER INSTRUCTIONS***
At 1500 cycles, the opener may turn on a “service due reminder”
(delay to close). To disable do the following:
Turn off
the power (or press and hold the reset button)
Press and hold
the case lid button
Turn on
the power (or release the reset button)
Release
the case lid button after ACK flashes three times
Note
the two confirmation ACK flashes