background image

18

Component removal & reinstallation

1. Inspect the front glass seal for damage before refitting. Replacement front glasses and seals are

available from Martin Architectural dealers (front glass: p/n 41700007, front glass seal: p/n
20600441).

2. Inspect the six countersunk Allen screws from the trim ring before reuse. Threads must be clean

and undamaged. Two spare screws are supplied with the fixture. Replacement screws are
available from Martin Architectural dealers (p/n: 08111314)

3. Refit the lens by lowering it into the housing, making sure that the screw in the seating engages

in the notch in the lens flange.

4. Place the front glass complete with its seal in the top of the housing and place the trim ring over

the front glass.

5. To make future service easier, apply a small amount of copper-based or silicone grease to the

threads of the trim ring screws before insertion.

6. See illustration below. Gradually cross-tighten the trim ring screws in the sequence illustrated to

1.8 Nm/1.3 ft-lbs.

Important! Cross-tighten gradually. Do not exceed the maximum torque of 1.8 Nm/1.3 ft-lbs., or 

you may distort the trim ring and damage the seal. This will impair the Inground 
200’s waterproof properties and invalidate the product warranty.

 

Lamp module: removal and refitting

This section describes removal and refitting of the lamp module to gain access to the connections
and PCB/power compartments at the bottom of the fixture. If you need to replace the lamp, please
refer to the Inground 200 User Manual.

To remove the lamp module:

1. Isolate the Inground 200 from AC power and allow to cool for at least 15 minutes.

2. Remove the front glass with seal and lens (see 

“Front glass and lens: removal and refitting”

 on

page 17).

3. Do not loosen the beam adjustment screws and avoid disturbing the beam adjustment settings.

Holding the lamp module by the beam adjustment ring, gently lift the whole module upwards until
it is clear of the housing. Note the positions of the lamp module wiring connectors, then
disconnect them and lift the lamp module out of the housing. 

To refit the lamp module:

1. Reconnect the lamp module wiring connectors.

2. Note the position of the screw in the lamp module seating in the housing. Lower the lamp module

into the housing, rotating it if necessary so that the notch in the top of the lamp module engages
with the screw. The lamp module is now correctly oriented.

3. If beam settings have been disturbed, readjust the beam (see 

“Beam adjustment”

 on page 16).

4. Refit the lens, front glass with its seal and trim ring, and cross-tighten the trim ring screws

gradually to 1.8 Nm/1.3 ft-lbs (see 

“Front glass and lens: removal and refitting”

 on page 17).

A

B

C

D

E

F

Summary of Contents for Inground 200

Page 1: ...mar tinar chi te ctural Installation Guide Inground 200...

Page 2: ...ghts reserved No part of this guide may be reproduced in any form or by any means with out permission in writing from Martin Professional A S Denmark Printed in Denmark P N 35000151 Rev B 340 310 7 49...

Page 3: ...9 Direct burial examples 10 Cable installation 10 Cable slack 10 6 Power and data connection 11 AC power supply 11 Power supply settings 11 Cable glands 11 Connecting power supply cables 11 Control d...

Page 4: ......

Page 5: ...nd 200 6 Color and Full Spectrum CMY models are also supplied with the following items 2 stainless steel IP68 cable glands for control cable entry M16 x 1 5 designed for cable 5 9mm 0 2 0 35 in 2 Safe...

Page 6: ...rn or restrict access To avoid accidents during installation or service restrict access to the site and place both warning notices and barriers around all work areas until work is completed and all co...

Page 7: ...to ensure that all national safety regulations and legal requirements are followed when installing the Inground 200 Choosing a location Safety The Inground 200 must be installed in a location that mee...

Page 8: ...viest rain or snowfall in the area where the Inground 200 is located To minimize the risk of flooding or waterlogging install the fixture in a location which is above the level of the surrounding area...

Page 9: ...e Martin Architectural website at http www martin architectural com for full details The Inground 200 in a correctly installed drive over installation sleeve will support a weight of 5000kg from a veh...

Page 10: ...y of achieving this is to pack crushed stone or hardcore firmly in the bottom of the installation well to support the housing Ensure that cables are not stressed or crushed during installation and ens...

Page 11: ...figured at the factory for one of the two power supply settings listed in Table 1 below The factory power supply settings are printed on the product serial number labels outside and inside the housing...

Page 12: ...5 Prevent the cable entry from turning by holding it with a wrench Tighten the compression nut sufficiently to make a water resistant seal Do not over tighten as this may damage the seal 6 If power c...

Page 13: ...ned for burial for this purpose RS 485 cable has low capacitance and a characteristic impedance of 85 to 150 ohms It is electrically shielded and has at least 1 twisted pair of conductors The minimum...

Page 14: ...it for access see Connecting power supply cables on page 11 3 Working from outside the fixture unscrew a smaller blanking plug Dismantle a data cable gland and screw the cable entry into the hole in...

Page 15: ...after a short delay When programmable Inground 200 models are powered on for the first time they will run through a factory set light show for test purposes They will continue to run this test sequenc...

Page 16: ...re is at optimum temperature for adjustment by following one of these two alternatives a If the fixture has been in operation before you want to adjust the beam do not switch it off Instead remove the...

Page 17: ...eplacement and cable connection require the removal and reinstallation of certain components This section contains instructions for these procedures Front glass and lens removal and refitting A 4mm Al...

Page 18: ...Lamp module removal and refitting This section describes removal and refitting of the lamp module to gain access to the connections and PCB power compartments at the bottom of the fixture If you need...

Page 19: ...holes M25 x 1 5 thread length 8mm 0 31 in AC power cable glands 2 x stainless steel IP 68 M25 x 1 5 13 17mm 0 51 0 67 in Control data cable entry 2 x threaded holes M16 x 1 5 thread length 8mm 0 31 in...

Page 20: ...www martin architectural com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Reviews: