Please read these assembly instructions carefully before starting the
installation.
This appliance is not intended for use by persons(including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they do
not play with the appliance.
Caution
Ensure that all electric power is turned
off before carrying out any work.
Electrical work may only be performed
by authorised personnel and in accord-
ance with the applicable regulations.
Wall or ceiling installation
➊
Install the ventilation duct into the wall or ceiling. For wall installation ensure there is a
slight gradient (~2°) towards the outside. For ceiling installation you must insulate the
air duct if it passes through unheated areas.
➋
Glue the foam tapes all around sections (A) according to the size of duct used.
➌
Remove the cover (B) and connect the fan according to circuit diagram (D).
➍
Secure the cable near the cable entry using the strain relief and rubber ring and
replace the cover.
➎
Insert the fan into the ventilation duct – Please note: ensure direction arrow (C) on the
fan's type plate is pointing in the direction of the desired air flow.
➏
Fit protective grating onto both ends of the ventilation duct for additional protection
against moisture and contact with moving parts.
Important information
• The voltage and frequency of the power supply must comply with the fan's specifica-
tions.
• The installation site must have an all-pole disconnecting device from the mains with a
contact opening width of at least 3 mm.
• The fans are double-insulated and do not require a protective earth conductor.
• Installation in rooms with high moisture must be performed according to DIN/VDE
0100 T 701.
• If operated near a fireplace with chimney, care must be taken to ensure that sufficient
air can enter the room being ventilated.
• Use a soft brush or damp cloth to clean, do not use any solvents.
Circuit diagram (D)
Technical data
C10 (MC 100 E) C20 (MC 125 E) C30 (MC 150 E)
• Protection class/type:
IP 24
IP 24
IP 24
• Mains voltage:
230 V~50 Hz
230 V~50 Hz
230 V~50 Hz
• Power consumption:
12 W
15 W
29 W
• Air flow rate:
90 m
3
/h
150 m
3
/h
230 m
3
/h
• Noise level:
31 dB(A) 3m
34 dB(A) 3m
37 dB(A) 3m
Technical alterations reserved.