Marlec Eng Co Ltd Installation Instructions
__________________________________________________________________________________________
Document No: SM124 Issue D 30.01.07
18
its pole for the following tests.
•
Check the brushes and slipring for wear or damage.
To inspect the brushes,
remove the cover from the main housing by removing the four fixing screws.
The brushes and slipring can be then be inspected by removing the four self-
tapping screws holding the brush holder assembly in place. Remove any black
deposits from slipring with emery paper. Heavy deposits and reduced power
indicate a possible reverse connection to the battery (see Page 11).
•
Check hub for free rotation with generator disconnected from battery.
If the hub does not rotate freely, check for a possible short circuit in the wiring.
If no wiring fault is found refer to your dealer or manufacturer.
If the above checks have identified a need for spare parts or failed to identify
the problem you should contact Marlec who can advise you of your nearest
distributor in their world wide network. In the first instance we recommend
that you contact the company from whom the product was originally
purchased.
If in doubt, refer to your dealer or manufacturer.