23
7.0 ADJUSTMENTS
WARNING: At least twice a year, have an authorized service person
clean and adjust the unit for maximum performance.
ADJUSTMENT FOR HIGH ALTITUDE LOCATIONS
The steamer has been factory set so that when it is ON, and during the READY phase, it will
below water boiling point). However, for high altitude locations, an authorized service agency
must adjust the steamer to achieve this temperature.
CAUTION: Shut off main electrical power to unit.
Door Gasket Replacement
The cooking compartment door gaskets are made of a silicone-type rubber material that is very
durable but subject to wear during normal operation. Should the gasket leak replace it.
1.
Open the cooking compartment door.
2.
Remove the four screws on the outside of the door frame, and remove the door
panel assembly.
3.
Remove the six screws from the gasket plate in the door panel assembly.
4.
Remove the gasket plate and the door gasket from door panel.
5.
Install the new door gasket to the door panel. Replace the gasket plate and six
screws.
6.
Reassemble the door panel assembly in the door frame using the four screws.
7.
Gasket replacement is now complete.
Door may be difficult to close until gasket has compressed to conform to opening. Leaving door
closed overnight will compress gasket.
Exterior Panel Removal
WARNING: To prevent hazard in servicing the cooker, be certain
that the steam supply boiler is shut down, the cold water shut-off
valve is closed, and the electrical disconnect circuit breaker for the
Cooker/Boiler unit is OFF before removing side panels.
Access to all internal plumbing and electrical assemblies is from the right side. The right-side
panel is removed by removing the bottom screws from panel.