![Market Forge Industries MPS-3E Owner'S Manual Download Page 23](http://html.mh-extra.com/html/market-forge-industries/mps-3e/mps-3e_owners-manual_1728033023.webp)
20
PROBLEM
PROBABLE CAUSE
REMEDY
Water not being supplied to
Generator.
a.
Water supply off.
b.
Supply water pressure too
low.
c.
Defective water solenoid
valve.
d.
Level Probe shorted.
e.
Defective water level
control.
f.
Drain valve is open.
g.
Water supply off.
a.
Check incoming water
valve is on.
b.
Call supply agency.
c.
Replace or clean.
d.
Check and correct.
e.
Replace.
f.
Check valve, clean or
replace.
g.
Check incoming water
valve is on.
NOTE: THESE PROBLEMS ARE AN INDICATION OF SEVERE WATER CONDITIONS WHICH
SHOULD BE CORRECTED IMMEDIATELY TO AVOID DAMAGE TO THE COMPONENTS AND
PERFORMANCE OF THE STEAMER.
CALL YOUR SERVICE AGENCY FOR ASSISTANCE.
Summary of Contents for MPS-3E
Page 27: ...24 8 0 PARTS FIGURE 3 Exploded View ...
Page 33: ...30 9 0 WIRING ...
Page 34: ...31 9 0 WIRING Continued ...
Page 35: ...32 9 0 WIRING Continued ...
Page 36: ...33 9 0 WIRING Continued ...
Page 37: ...34 9 0 WIRING Continued ...
Page 38: ...35 9 0 WIRING Continued ...