Installation Basics
Unpacking the Unit
When the 2-piece heat pump reaches its destination it
should be unpacked to determine if any damage has occurred
during shipment. Any visible damage should be noted on the
carrier's freight bill and a suitable claim filed at once.
Indoor Unit Placement
For air to air units, to achieve the greatest efficiency, the
indoor unit should be centrally located in the home with respect
to the conditioned space. A heating system cannot be expected
to produce an even temperature throughout the house when it is
located at one end of the structure and the air is transmitted with
uninsulated metal ductwork.
If possible the front access panel and side access panel
opposite the air return should remain clear of obstruction for a
distance of
two feet
to facilitate servicing and general
maintenance. No access is required on the back side. Ensure
the unit is level to eliminate any possible condensate draining
issues.
Raising the indoor unit off the floor a few inches is
generally a good practice since this will prevent rusting of the
bottom panel of the unit and deaden vibrations. An anti-
vibration pad, available as an accessory, or a piece of 2”
styrofoam should be placed under the unit. Be careful not to run
piping in front of the filter rack access cover, since access is
required in order to change the air filter.
WARNING: Pool chemicals should be stored
in a different room from the PC unit to pre-
vent premature corrosion problems.
WARNING: Pool chemicals should be inject-
ed downstream of the PC unit.
Sample Bill of Materials
Although not exhaustive, following is a list of materials needed
for a typical installation:
FROM MARITIME GEOTHERMAL
• ATF SERIES HEAT PUMP (L OR R RETURN)
W/ACE OUTDOOR UNIT
• PLENUM HEATER __kW
• AIR THERMOSTAT (WIFI OR STD)
• SHIELDED 18-8 WIRE FOR OUTDOOR UNIT
• BUFFER TANK W/ELEMENTS __kW
OPTIONAL FROM MARITIME GEOTHERMAL
• ANTI-VIBRATION PAD FOR UNDER UNIT
• SOUND JACKET
• COMPRESSOR SECURE START
• ELECTROSTATIC (CLEANABLE) AIR FILTER
DUCTWORK
• OUTLET PLENUM ADAPTER W/ FLEXIBLE COLLAR
• RETURN AIR ADAPTER W/ FLEXIBLE COLLAR
• FIBREGLASS INSULATION (FOR NOISE, IF REQ’D)
• TRUNK DUCT W/ JOINERS (IF NOT EXISTING)
• 6” ROUND DUCT W/ADAPTERS (IF NOT EXISTING)
• ALUMINUM TAPE
• SHEET METAL SCREWS
DHW:
• PREHEAT TANK, 40 OR 60 GAL
• ½” COPPER PIPE
• ½” FITTINGS, BALL VALVES, BOILER DRAINS, CV
ELECTRICAL
• HEAT PUMP SERVICE WIRE: 6-2/3 OR 8-2/3
• PLENUM HEATER SERVICE WIRE
• 14-2 OUTDOOR RATED WIRE W/ DISCONNECT
SWITCH FOR OUTDOOR UNIT
• HEAT PUMP BREAKER
• PLENUM HEATER BREAKER
• THERMOSTAT WIRE 18-8
• THERMOSTAT WIRE 18-3 (PLENUM HEATER)
• FORK TERMINALS FOR TSTAT WIRE (6)
• CONDENSATE PUMP & HOSE (IF REQUIRED)
REFRIGERATION
• 1/2” & 7/8” (OR 3/8” & 3/4”) ACR TUBING
• PIPE ISULATION
• EXTRA R410A REFRIGERANT FOR LINESETS >25 FT
INFLOOR ZONES
• CIRCULATOR: HEAT PUMP TO TANK
• 1” PIPE & FITTINGS: HEAT PUMP TO TANK
• ZONE CIRCULATOR(S)
• ZONE TRANSFORMER & CIRC CONTACTOR
• ZONE VALVES (IF NOT INDIVIDUAL PUMPS)
• IN-FLOOR PIPING
• ZONE THERMOSTATS
• RELAYS OR ZONE CONTROLLER
• ZONE SUPPLY & RETURN HEADERS:
1” COPPER PIPE & FITTINGS
• PIPE & FITTINGS TO ZONES
• EXPANSION TANK
• 2” STYROFOAM INSUL. (IF PAD NOT PURCHASED)
Summary of Contents for ATF-45
Page 12: ...Page 12 002000MAN 01 1 Jun 2018...
Page 15: ...1 Jun 2018 Page 15 002000MAN 01...
Page 16: ...Page 16 002000MAN 01 1 Jun 2018...
Page 17: ...1 Jun 2018 Page 17 002000MAN 01...
Page 18: ...Page 18 002000MAN 01 1 Jun 2018...
Page 20: ...Page 20 002000MAN 01 1 Jun 2018...
Page 21: ...1 Jun 2018 Page 21 002000MAN 01...
Page 22: ...Page 22 002000MAN 01 1 Jun 2018...
Page 23: ...1 Jun 2018 Page 23 002000MAN 01...
Page 24: ...Page 24 002000MAN 01 1 Jun 2018...
Page 25: ...1 Jun 2018 Page 25 002000MAN 01...
Page 27: ...1 Jun 2018 Page 27 002000MAN 01...
Page 31: ...1 Jun 2018 Page 31 002000MAN 01...
Page 84: ...Page 84 002000MAN 01 1 Jun 2018 Wiring Diagram 208 230 1 60...
Page 85: ...1 Jun 2018 Page 85 002000MAN 01 Electrical Box Layout 208 230 1 60...
Page 86: ...Page 86 002000MAN 01 1 Jun 2018 Wiring Diagram 208 3 60...
Page 87: ...1 Jun 2018 Page 87 002000MAN 01 Electrical Box Layout 208 3 60...
Page 88: ...Page 88 002000MAN 01 1 Jun 2018 Wiring Diagram 460 3 60...
Page 89: ...1 Jun 2018 Page 89 002000MAN 01 Electrical Box Layout 460 3 60...
Page 90: ...Page 90 002000MAN 01 1 Jun 2018 ACE 45 55 Wiring Diagram ACE 65 75 Wiring Diagram...
Page 91: ...1 Jun 2018 Page 91 002000MAN 01...
Page 92: ...Page 92 002000MAN 01 1 Jun 2018...
Page 93: ...1 Jun 2018 Page 93 002000MAN 01...
Page 94: ...Page 94 002000MAN 01 1 Jun 2018 Dimensions ATF 45 Left Return INDOOR UNIT OUTDOOR UNIT ACE 45...
Page 95: ...1 Jun 2018 Page 95 002000MAN 01 INDOOR UNIT OUTDOOR UNIT ACE 45 Dimensions ATF 45 Right Return...
Page 96: ...Page 96 002000MAN 01 1 Jun 2018 INDOOR UNIT OUTDOOR UNIT ACE 55 Dimensions ATF 55 Left Return...
Page 97: ...1 Jun 2018 Page 97 002000MAN 01 INDOOR UNIT OUTDOOR UNIT ACE 55 Dimensions ATF 55 Right Return...
Page 100: ...Page 100 002000MAN 01 1 Jun 2018 ACE 65 75 ACE 45 55...