CLMD16 Configuration Guide Rev.1.1 25
Step 1:
Choose appropriate output
rules for the “Logic Elements”:
In this example Discrete I/O 1 is “Navigation Lights” and Discrete I/O 2 is “Anchor Light”.
Where 0 is Off and 1 is On, attention to the logic output correlation to the input combination
must be paid for proper operation. Just as the previous circuit above (
“Navigation / Anchor
Lights Toggle Logic using two Momentary Input Signals”
), there will be rulesets that allow for
Logic Output operation to occur only when the status of a breaker is already On for the “Logic
Elements” associated with “Navigation Lights” ECB and “Anchor Light” (Aft Mast) ECBs. Notice
the “Logic Element” associated with the “Steaming Light” ECB allows for the ECB to turn On
when either ECB 1 (Navigation) or ECB 2 (Anchor) is in the On state.