Fault Check Procedures
- 32 -
Removing Camera Case
(See also Diagram Page 25)
1)
Remove the harness and the main part of the insulation muff.
2)
Disconnect the voltage stabiliser unit by unplugging the in-line
connector situated by the pistol grip.
3)
Hold the camera with the lens uppermost, depress the front
plate and rotate the breech ring clockwise to unlock the case.
4)
Remove the camera from its rear case.
5)
To replace, reverse the above procedure, whenever possible a
new sealing ring should be fitted.
Connecting External Power Supply
1)
Switch off the camera.
2)
Remove battery cartridge from the voltage stabiliser unit.
3)
Plug in battery substitution unit P4428D.
4)
Connect the red lead to +12V and the black lead to 0V of a
current limited 1A d.c. supply.
Connecting External Monitor
1)
Using a suitable lead with BNC connectors plug the monitor into
the video socket located on the front plate of the camera.
2)
Ensure the monitor is terminated in 75 ohms.